10 CFR 20.1004 - Units of radiation dose.

§ 20.1004 Units of radiation dose.
(a) Definitions. As used in this part, the units of radiation dose are:
Gray (Gy) is the SI unit of absorbed dose. One gray is equal to an absorbed dose of 1 Joule/kilogram (100 rads).
Rad is the special unit of absorbed dose. One rad is equal to an absorbed dose of 100 ergs/gram or 0.01 joule/kilogram (0.01 gray).
Rem is the special unit of any of the quantities expressed as dose equivalent. The dose equivalent in rems is equal to the absorbed dose in rads multiplied by the quality factor (1 rem=0.01 sievert).
Sievert is the SI unit of any of the quantities expressed as dose equivalent. The dose equivalent in sieverts is equal to the absorbed dose in grays multiplied by the quality factor (1 Sv=100 rems).
(b) As used in this part, the quality factors for converting absorbed dose to dose equivalent are shown in table 1004(b).1.
Table 1004(b).1—Quality Factors and Absorbed Dose Equivalencies
Type of radiation Quality factor Absorbed dose equal to a unit dose equivalent a
(Q)
a Absorbed dose in rad equal to 1 rem or the absorbed dose in gray equal to 1 sievert.
X-, gamma, or beta radiation 1 1
Alpha particles, multiple-charged particles, fission fragments and heavy particles of unknown charge 20 0.05
Neutrons of unknown energy 10 0.1
High-energy protons 10 0.1
(c) If it is more convenient to measure the neutron fluence rate than to determine the neutron dose equivalent rate in rems per hour or sieverts per hour, as provided in paragraph (b) of this section, 1 rem (0.01 Sv) of neutron radiation of unknown energies may, for purposes of the regulations in this part, be assumed to result from a total fluence of 25 million neutrons per square centimeter incident upon the body. If sufficient information exists to estimate the approximate energy distribution of the neutrons, the licensee may use the fluence rate per unit dose equivalent or the appropriate Q value from table 1004(b).2 to convert a measured tissue dose in rads to dose equivalent in rems.
Table 1004(b).2—Mean Quality Factors, Q, and Fluence per Unit Dose Equivalent for Monoenergetic Neutrons
Neutron energy (MeV) Quality factor a (Q) Fluence per unit dose equivalent b (neutrons cm−2 rem −1)
a Value of quality factor (Q) at the point where the dose equivalent is maximum in a 30-cm diameter cylinder tissue-equivalent phantom.
b Monoenergetic neutrons incident normally on a 30-cm diameter cylinder tissue-equivalent phantom.
(thermal) 2.5×10 −8 2 980×10 6
1×10 −7 2 980×10 6
1×10 −6 2 810×10 6
1×10 −5 2 810×10 6
1×10 −4 2 840×10 6
1×10 −3 2 980×10 6
1×10 −2 2.5 1010×10 6
1×10 − 1 7.5 170×10 6
5×10 −1 11 39×10 6
1 11 27×10 6
2.5 9 29×10 6
5 8 23×10 6
7 7 24×10 6
10 6.5 24×10 6
14 7.5 17×10 6
20 8 16×10 6
40 7 14×10 6
60 5.5 16×10 6
1×10 2 4 20×10 6
2×10 2 3.5 19×10 6
3×10 2 3.5 16×10 6
4×10 2 3.5 14×10 6

Title 10 published on 2014-01-01

no entries appear in the Federal Register after this date.

Title 10 published on 2014-01-01

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 10 CFR 20 after this date.

  • 2014-07-25; vol. 79 # 143 - Friday, July 25, 2014
    1. 79 FR 43284 - Radiation Protection
      GPO FDSys XML | Text
      NUCLEAR REGULATORY COMMISSION
      Advance notice of proposed rulemaking; request for comments.
      Submit comments by November 24, 2014. Comments received after this date will be considered if it is practical to do so, but the NRC is only able to ensure consideration of comments received on or before this date.
      10 CFR Part 20