40 CFR 411.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

§ 411.22 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic Effluent limitations (maximum for any 1 day)
Metric units (kg/kkg of dust leached)
TSS 0.4.
Temperature (heat) Not to exceed 3 °C rise above inlet temperature.
pH Within the range 6.0 to 9.0.
English units (lb/1,000 lb of dust leached)
TSS 0.4.
Temperature (heat) Not to exceed 3 °C rise above inlet temperature.
pH Within the range 6.0 to 9.0.
[39 FR 6591, Feb. 20, 1974, as amended at 60 FR 33951, June 29, 1995]

Title 40 published on 2013-07-01

no entries appear in the Federal Register after this date.

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.


United States Code