40 CFR 413.04 - Standards for integrated facilities.
prev | next
§ 413.04
Standards for integrated facilities.
Pretreatment standards for integrated facilities shall be computed as required by § 403.6(e) of EPA's General Pretreatment Regulations. In cases where electroplating process wastewaters are combined with regulated wastewaters which have 30 days average standards, the corresponding 30 day average standard for the electroplating wastewaters must be used. The 30 day average shall be determined for pollutants in the relevant subcategory from the corresponding daily and 4 day average values listed in the table below.
| If the maximum for any 1 day is | And the 4 day average is | Then the 30 day average is |
|---|---|---|
| 0.6 | 0.4 | 0.3 |
| 1.2 | .7 | .5 |
| 1.9 | 1 | .55 |
| 4.1 | 2.6 | 1.8 |
| 4.2 | 2.6 | 1.8 |
| 4.5 | 2.7 | 1.8 |
| 5.0 | 2.7 | 1.5 |
| 7.0 | 4 | 2.5 |
| 10.5 | 6.8 | 5 |
| 20.0 | 13.4 | 10 |
| 23 | 16 | 12 |
| 47 | 29 | 20 |
| 53 | 36 | 27 |
| 74 | 39 | 21 |
| 107 | 65 | 45 |
| 169 | 89 | 49 |
| 160 | 100 | 70 |
| 164 | 102 | 70 |
| 176 | 105 | 70 |
| 273 | 156 | 98 |
| 365 | 229 | 160 |
| 374 | 232 | 160 |
| 401 | 241 | 160 |
| 410 | 267 | 195 |
| 623 | 257 | 223 |
| 935 | 609 | 445 |
Title 40 published on 2012-07-01
no entries appear in the Federal Register after this date.
This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.
This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].
It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.