§ 63.7898 How do I demonstrate continuous compliance with the emissions limitations and work practice standards for tanks?
(a) You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7895 applicable to your affected tanks by meeting the requirements in paragraphs (b) through (d) of this section.
(b) You must demonstrate continuous compliance with the requirement to determine the applicable tank control level specified in § 63.7895(b) for each affected tank by meeting the requirements in paragraphs (b)(1) through (3) of this section.
(1) Keeping records of the tank design capacity according to the requirements in § 63.1065(a).
(2) For tanks subject to § 63.7886(b)(1)(ii) and not using Tank Level 2 controls, meeting the requirements in paragraphs (b)(2)(i) and (ii) of this section.
(i) Keeping records of the maximum HAP vapor pressure determined according to the procedures in § 63.7944 for the remediation material placed in each affected tank.
(ii) Performing a new determination of the maximum HAP vapor pressure whenever changes to the remediation material managed in the tank could potentially cause the maximum HAP vapor pressure to increase to a level that is equal to or greater than the maximum HAP vapor pressure for the tank design capacity specified in Table 2. You must keep records of each determination.
(3) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(c) You must demonstrate continuous compliance for each tank determined to require Tank Level 1 controls by meeting the requirements in paragraphs (c)(1) through (5) of this section.
(1) Operating and maintaining the fixed roof and closure devices according to the requirements in § 63.902(c).
(2) Visually inspecting the fixed roof and closure devices for defects at least annually according to the requirements in § 63.906(a).
(3) Repairing defects according to the requirements in § 63.63.906(b).
(4) Recording the information specified in § 63.907(a)(3) and (b).
(5) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(d) You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a fixed roof with an internal floating roof according to § 63.7895(d)(1) by meeting the requirements in paragraphs (d)(1) through (5) of this section.
(1) Operating and maintaining the internal floating roof according to the requirements in § 63.1063(b).
(2) Visually inspecting the internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
(3) Repairing defects according to the requirements in § 63.1063(e).
(4) Recording the information specified in § 63.1065(b) through (d).
(5) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(e) You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using an external floating roof according to § 63.7895(d)(2) by meeting the requirements in paragraphs (e)(1) through (5) of this section.
(1) Operating and maintaining the external floating roof according to the requirements in § 63.1063(b).
(2) Visually inspecting the external floating roof according to the requirements in § 63.1063(d)(1) and inspecting the seals according to the requirements in § 63.1063(d)(2) and (3).
(3) Repairing defects according to the requirements in § 63.1063(e).
(4) Recording the information specified in § 63.1065(b) through (d).
(5) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(f) You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a fixed roof vented to a control device according to § 63.7895(d)(3) by meeting the requirements in paragraphs (f)(1) through (6) of this section.
(1) Operating and maintaining the fixed roof and closure devices according to the requirements in § 63.685(g).
(2) Visually inspecting the fixed roof and closure devices for defects at least annually according to the requirements in § 63.695(b)(3)(i).
(3) Repairing defects according to the requirements in § 63.695(b)(4).
(4) Recording the information specified in § 63.696(e).
(5) Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
(6) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(g) You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and operated as a pressure tank according to § 63.7895(d)(4) by meeting the requirements in paragraphs (g)(1) through (3) of this section.
(1) Operating and maintaining the pressure tank and closure devices according to the requirements in § 63.685(h).
(2) Visually inspecting each pressurized tank and closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h), and recording the results of each inspection.
(3) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(h) You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5) by meeting the requirements in paragraphs (h)(1) through (4) of this section.
(1) Performing the verification procedure for the enclosure annually according to the requirements in § 63.685(i).
(2) Recording the information specified in § 63.696(f).
(3) Meeting each applicable requirement for demonstrating continuous compliance with the emissions limitations and work practice standards for a closed vent system and control device in § 63.7928.
(4) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006]

Title 40 published on 2014-07-01

The following are only the Rules published in the Federal Register after the published date of Title 40.

For a complete list of all Rules, Proposed Rules, and Notices view the Rulemaking tab.

  • 2014-11-25; vol. 79 # 227 - Tuesday, November 25, 2014
    1. 79 FR 70102 - National Emission Standards for Hazardous Air Pollutants; Delegation of Authority to Texas
      GPO FDSys XML | Text
      ENVIRONMENTAL PROTECTION AGENCY
      Direct final rule; delegation of authority.
      This rule is effective on January 26, 2015 without further notice, unless EPA receives relevant adverse comment by December 26, 2014. If EPA receives such comment, EPA will publish a timely withdrawal in the Federal Register informing the public that this rule will not take effect.
      40 CFR Part 63

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.


United States Code

Title 40 published on 2014-07-01

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 40 CFR 63 after this date.

  • 2014-12-12; vol. 79 # 239 - Friday, December 12, 2014
    1. 79 FR 73872 - Phosphoric Acid Manufacturing and Phosphate Fertilizer Production RTR and Standards of Performance for Phosphate Processing; Extension of Comment Period
      GPO FDSys XML | Text
      ENVIRONMENTAL PROTECTION AGENCY
      Notice of proposed rulemaking; extension of public comment period.
      Comments. The public comment period for the proposed rule published in the Federal Register on November 7, 2014, (79 FR 66512) is being extended for 30 days to January 21, 2015.
      40 CFR Parts 60 and 63