Pollutant Analyzer type Hydro-chloric acid Ammonia Hydrogensulfide Sulfur dioxide Nitrogen dioxide Nitric oxide Carbon dioxide Ethylene Ozone Mxy-lene Water vapor Carbon monoxide Methane Ethane Naphthalene
1 Concentrations of interferent listed must be prepared and controlled to ±10 percent of the stated value.
2 Analyzer types not listed will be considered by the Administrator as special cases.
3 Do not mix with the pollutant.
4 Concentration of pollutant used for test. These pollutant concentrations must be prepared to ±10 percent of the stated value.
5 If candidate method utilizes an elevated-temperature scrubber for removal of aromatic hydrocarbons, perform this interference test.
6 If naphthalene test concentration cannot be accurately quantified, remove the scrubber, use a test concentration that causes a full scale response, reattach the scrubber, and evaluate response for interference.
SO2 Ultraviolet fluorescence 5 0.1 4 0.14 0.5 0.5 0.5 0.2 20,000 6 0.05
SO2 Flame photometric 0.01 4 0.14 750 3 20,000 50
SO2 Gas chromatography 0.1 4 0.14 750 3 20,000 50
SO2 Spectrophotometric-wet chemical (pararosanaline) 0.2 0.1 0.1 4 0.14 0.5 750 0.5
SO2 Electrochemical 0.2 0.1 0.1 4 0.14 0.5 0.5 0.2 0.5 3 20,000
SO2 Conductivity 0.2 0.1 4 0.14 0.5 750
SO2 Spectrophotometric-gas phase, including DOAS 4 0.14 0.5 0.5 0.2
O3 Chemiluminescent 3 0.1 750 4 0.08 3 20,000
O3 Electrochemical 3 0.1 0.5 0.5 4 0.08
O3 Spectrophotometric-wet chemical (potassium iodide) 3 0.1 0.5 0.5 3 0.5 4 0.08
O3 Spectrophotometric-gas phase, including ultraviolet absorption and DOAS) 0.5 0.5 0.5 4 0.08 0.02 20,000
CO Non-dispersive Infrared 750 20,000 4 10
CO Gas chromatography with flame ionization detector 20,000 4 10 0.5
CO Electrochemical 0.5 0.2 20,000 4 10
CO Catalytic combustion-thermal detection 0.1 750 0.2 20,000 4 10 5.0 0.5
CO IR fluorescence 750 20,000 4 10 0.5
CO Mercury replacement-UV photometric 0.2 4 10 0.5
NO2 Chemiluminescent 3 0.1 0.5 4 0.1 0.5 20,000
NO2 Spectrophotometric-wet chemical (azo-dye reaction) 0.5 4 0.1 0.5 750 0.5
NO2 Electrochemical 0.2 3 0.1 0.5 4 0.1 0.5 750 0.5 20,000 50
NO2 Spectrophotometric-gas phase 3 0.1 0.5 4 0.1 0.5 0.5 20,000 50

Title 40 published on 2014-07-01

no entries appear in the Federal Register after this date.

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.


United States Code
U.S. Code: Title 42 - THE PUBLIC HEALTH AND WELFARE
Statutes at Large
Public Laws

91-604