40 CFR Appendix Table 5 to Subpart BBBB of Part 60 - Table 5 to Subpart BBBB of Part 60—Model Rule—Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

Table 5 to Subpart BBBB of Part 60—Model Rule—Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units
For the following municipal waste combustion units You must meet the following carbon monoxide limits a Using the following averaging times b
1. Fluidized bed 100 parts per million by dry volume 4-hour.
2. Fluidized bed, mixed fuel, (wood/refuse-derived fuel) 200 parts per million by dry volume 24-hour c.
3. Mass burn rotary refractory 100 parts per million by dry volume 4-hour.
4. Mass burn rotary waterwall 250 parts per million by dry volume 24-hour.
5. Mass burn waterwall and refractory 100 parts per million by dry volume 4-hour.
6. Mixed fuel-fired, (pulverized coal/refuse-derived fuel) 150 parts per million by dry volume 4-hour.
7. Modular starved-air and excess air 50 parts per million by dry volume 4-hour.
8. Spreader stoker, mixed fuel-fired (coal/refuse-derived fuel) 200 parts per million by dry volume 24-hour daily.
9. Stoker, refuse-derived fuel 200 parts per million by dry volume 24-hour daily.

a All emission limits (except for opacity) are measured at 7 percent oxygen. Compliance is determined by continuous emission monitoring systems.

b Block averages, arithmetic mean. See § 60.1940 for definitions.

c 24-hour block average, geometric mean.