40 CFR Appendix Table 1 to Subpart CCCCC of Part 63 - Table 1 to Subpart CCCCC of Part 63—Applicability of General Provisions to Subpart CCCCC
prev | next
Table 1 to Subpart CCCCC of Part 63—Applicability of General Provisions to Subpart CCCCC
As required in § 63.7350, you must comply with each applicable requirement of the NESHAP General Provisions (40 CFR part 63, subpart A) as shown in the following table:
Citation | Subject | Applies to Subpart CCCCC? | Explanation |
---|---|---|---|
§ 63.1 | Applicability | Yes | |
§ 63.2 | Definitions | Yes | |
§ 63.3 | Units and Abbreviations | Yes | |
§ 63.4 | Prohibited Activities | Yes | |
§ 63.5 | Construction/Reconstruction | Yes | |
§ 63.6(a), (b), (c), (d), (e), (f), (g), (h)(2)–(8) | Compliance with Standards and Maintenance Requirements | Yes | |
§ 63.6(h)(9) | Adjustment to an Opacity Emission Standard | Yes | |
§ 63.7(a)(3), (b), (c)–(h) | Performance Testing Requirements | Yes | |
§ 63.7(a)(1)–(2) | Applicability and Performance Test Dates | No | Subpart CCCCC specifies applicability and dates. |
§ 63.8(a)(1)–(3), (b), (c)(1)–(3), (c)(4)(i)–(ii), (c)(5)–(8), (d), (e), (f)(1)–(5), (g)(1)–(4) | Monitoring Requirements | Yes | CMS requirements in § 63.8(c)(4) (i)–(ii), (c)(5), and (c)(6) apply only to COMS for battery stacks. |
§ 63.8(a)(4) | Additional Monitoring Requirements for Control Devices in § 63.11 | No | Flares are not a control device for Subpart CCCCC affected sources. |
§ 63.8(c)(4) | Continuous Monitoring System (CMS) Requirements | No | Subpart CCCCC specifies requirements for operation of CMS. |
§ 63.8(e)(4)–(5) | Performance Evaluations | Yes | Except COMS performance evaluation must be conducted before the compliance date. |
§ 63.8(f)(6) | RATA Alternative | No | Subpart CCCCC does not require CEMS. |
§ 63.8(g)(5) | Data Reduction | No | Subpart CCCCC specifies data that can't be used in computing averages for COMS. |
§ 63.9 | Notification Requirements | Yes | Additional notifications for CMS in § 63.9(g) apply only to COMS for battery stacks. |
§ 63.10(a), (b)(1)–(b)(2)(xii), (b)(2)(xiv), (b)(3), (c)(1)–(6), (c)(9)–(15), (d), (e)(1)–(2), (e)(4), (f) | Recordkeeping and Reporting Requirements | Yes. | Additional records for CMS in § 63.10(c)(1)–(6), (9)–(15), and reports in § 63.10(d)(1)–(2) apply only to COMS for battery stacks. |
§ 63.10(b)(2) (xi)–(xii) | CMS Records for RATA Alternative | No | Subpart CCCCC doesn't require CEMS. |
§ 63.10(c)(7)–(8) | Records of Excess Emissions and Parameter Monitoring Exceedances for CMS | No | Subpart CCCCC specifies record requirements. |
§ 63.10(e)(3) | Excess Emission Reports | No | Subpart CCCCC specifies reporting requirements. |
§ 63.11 | Control Device Requirements | No | Subpart CCCCC does not require flares. |
§ 63.12 | State Authority and Delegations. | Yes | |
§§ 63.13–63.15 | Addresses, Incorporation by Reference, Availability of Information | Yes |