Table 3 to Subpart RRR of Part 63—Summary of Monitoring Requirements for New and Existing Affected Sources and Emission Units
Affected source/Emission unit Monitor type/Operation/Process Monitoring requirements
a Thermal chip dryers, scrap dryers/delacquering kilns/decoating kilns, dross-only furnaces, in-line fluxers and group 1 furnaces or melting/holding furnaces.
b Permitting agency may approve measurement devices of alternative accuracy, for example in cases where flux rates are very low and costs of meters of specified accuracy are prohibitive; or where feed/charge weighing devices of specified accuracy are not practicable due to equipment layout or charging practices.
c Non-triboelectric bag leak detectors must be installed and operated in accordance with manufacturers' specifications.
d Permitting agency may approve other alternatives including load cells for lime hopper weight, sensors for carrier gas pressure, or HCl monitoring devices at fabric filter outlet.
All affected sources and emission units with an add-on air pollution control device Emission capture and collection system Annual inspection of all emission capture, collection, and transport systems to ensure that systems continue to operate in accordance with ACGIH standards.
All affected sources and emission units subject to production-based (lb/ton of feed/charge) emission limits a Feed/charge weight Record weight of each feed/charge, weight measurement device or other procedure accuracy of ±1% b; calibrate according to manufacturers specifications, or at least once every 6 months.
Group 1 furnace, group 2 furnace, in-line fluxer, and scrap dryer/delacquering kiln/decoating kiln Labeling Check monthly to confirm that labels are intact and legible.
Aluminum scrap shredder with fabric filter Bag leak detector or Install and operate in accordance with “Fabric Filter Bag Leak Detection Guidance” c; record voltage output from bag leak detector.
COM or Design and install in accordance with PS-1; collect data in accordance with subpart A of 40 CFR part 63; determine and record 6-minute block averages.
VE Conduct and record results of 30-minute daily test in accordance with Method 9.
Thermal chip dryer with afterburner Afterburner operating temperature Continuous measurement device to meet specifications in § 63.1510(g)(1); record average temperature for each 15-minute block; determine and record 3-hr block averages.
Afterburner operation Annual inspection of afterburner internal parts; complete repairs in accordance with the OM&M plan.
Feed/charge material Record identity of each feed/charge; certify feed/charge materials every 6 months.
Scrap dryer/delacquering kiln/decoating kiln with afterburner and lime-injected fabric filter Afterburner operating temperature. Continuous measurement device to meet specifications in § 63.1510(g)(1); record temperature for each 15-minute block; determine and record 3-hr block averages.
Afterburner operation Annual inspection of afterburner internal parts; complete repairs in accordance with the OM&M plan.
Bag leak detector or Install and operate in accordance with “Fabric Filter Bag Leak Detection Guidance c; record voltage output from bag leak detector.
COM Design and Install in accordance with PS-1; collect data in accordance with subpart A of 40 CFR part 63; determine and record 6-minute block averages.
Lime injection rate For continuous injection systems, inspect each feed hooper or silo every 8 hours to verify that lime is free flowing; record results of each inspection. If blockage occurs, inspect every 4 hours for 3 days; return to 8-hour inspections if corrective action results in no further blockage during 3-day period, record feeder setting daily.
Fabric filter inlet temperature. Continous measurement device to meet specifications in § 63.1510(h)(2); record temperatures in 15-minute block averages; determine and record 3-hr block averages.
Sweat furnace with afterburner Afterburner operating temperature Continuous measurement device to meet specifications in § 63.1510(g)(1); record temperatures in 15-minute block averages; determine and record 3-hr block averages.
Afterburner operation Annual inspection of afterburner internal parts; complete repairs in accordance with the OM&M plan.
Dross-only furnace with fabric filter Bag leak detector or Install and operate in accordance with “Fabric Filter Bag Leak Detection Guidance” c; record output voltage from bag leak detector.
COM Design and install in accordance with PS-1; collect data in accordance with subpart A of 40 CFR part 63; determine and record 6-minute block averages.
Feed/charge material Record identity of each feed/charge; certify charge materials every 6 months.
Rotary dross cooler with fabric filter Bag leak detector or Install and operate in accordance with “Fabric Filter Bag Leak Detection Guidance” c; record output voltage from bag leak detector.
COM Design and install in accordance with PS-1; collect data in accordance with subpart A of 40 CFR part 63; determine and record 6-minute block averages.
In-line fluxer with lime-injected fabric filter Bag leak detector or Install and operate in accordance with “Fabric Filter Bag Leak Detection Guidance” c; record output voltage from bag leak detector.
COM Design and install in accordance with PS-1; collect data in accordance with subpart A of 40 CFR part 63; determine and record 6-minute block averages
Reactive flux injection rate Weight measurement device accuracy of ±1% b; calibrate according to manufacturer's specifications or at least once every 6 months; record time, weight and type of reactive flux added or injected for each 15-minute block period while reactive fluxing occurs; calculate and record total reactive flux injection rate for each operating cycle or time period used in performance test; orAlternative flux injection rate determination procedure per § 63.1510(j)(5).
Lime injection rate For continuous injection systems, record feeder setting daily and inspect each feed hopper or silo every 8 hrs to verify that lime is free-flowing; record results of each inspection. If blockage occurs, inspect every 4 hrs for 3 days; return to 8-hour inspections if corrective action results in no further blockage during 3-day period. d
In-line fluxer using no reactive flux Flux materials Record flux materials; certify every 6 months for no reactive flux.
Group 1 furnace with lime-injected fabric filter Bag leak detector or Install and operate in accordance with “Fabric Filter Bag Leak Detection Guidance” c; record output voltage from bag leak detector.
COM Design and install in accordance with PS-1; collect data in accordance with subpart A of 40 part CFR 63; determine and record 6-minute block averages.
Lime injection rate For continuous injection systems, record feeder setting daily and inspect each feed hopper or silo every 8 hours to verify that lime is free-flowing; record results of each inspection. If blockage occurs, inspect every 4 hours for 3 days; return to 8-hour inspections if corrective action results in no further blockage during 3-day period. d
Reactive flux injection rate Weight measurement device accuracy of ±1%b; calibrate every 3 months; record weight and type of reactive flux added or injected for each 15-minute block period while reactive fluxing occurs; calculate and record total reactive flux injection rate for each operating cycle or time period used in performance test; or Alternative flux injection rate determination procedure per § 63.1510(j)(5).
Fabric filter inlet temperature Continuous measurement device to meet specifications in § 63.1510(h)(2); record temperatures in 15-minute block averages; determine and record 3-hour block averages.
Maintain molten aluminum level in sidewell furnace Maintain aluminum level operating log; certify every 6 months.
Group 1 furnace without add-on controls Fluxing in sidewell furnace hearth Maintain flux addition operating log; certify every 6 months.
Reactive flux injection rate Weight measurement device accuracy of 1% b; calibrate according to manufacturers specifications or at least once every six months; record weight and type of reactive flux added or injected for each 15-minute block period while reactive fluxing occurs; calculate and record total reactive flux injection rate for each operating cycle or time period used in performance test.
OM&M plan (approved by permitting agency) Demonstration of site-specific monitoring procedures to provide data and show correlation of emissions across the range of charge and flux materials and furnace operating parameters.
Feed material (melting/holding furnace) Record type of permissible feed/charge material; certify charge materials every 6 months.
Clean (group 2) furnace Charge and flux materials Record charge and flux materials; certify every 6 months for clean charge and no reactive flux.
[65 FR 15710, Mar. 23, 2000, as amended at 69 FR 53985, Sept. 3, 2004]

Title 40 published on 2013-07-01

The following are only the Rules published in the Federal Register after the published date of Title 40.

For a complete list of all Rules, Proposed Rules, and Notices view the Rulemaking tab.

  • 2014-02-27; vol. 79 # 39 - Thursday, February 27, 2014
    1. 79 FR 11228 - Revisions to Test Methods and Testing Regulations
      GPO FDSys XML | Text
      ENVIRONMENTAL PROTECTION AGENCY
      Final rule.
      This final rule is effective on February 27, 2014. The incorporation by reference materials listed in the rule are approved by the Director of the Federal Register as of February 27, 2014.
      40 CFR Parts 51, 60, 61, and 63

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.


United States Code

Title 40 published on 2013-07-01

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 40 CFR 63 after this date.

  • 2014-02-27; vol. 79 # 39 - Thursday, February 27, 2014
    1. 79 FR 11228 - Revisions to Test Methods and Testing Regulations
      GPO FDSys XML | Text
      ENVIRONMENTAL PROTECTION AGENCY
      Final rule.
      This final rule is effective on February 27, 2014. The incorporation by reference materials listed in the rule are approved by the Director of the Federal Register as of February 27, 2014.
      40 CFR Parts 51, 60, 61, and 63