42 USC § 6295 - Energy conservation standards
| Energy Standards Equations | |
|---|---|
| Refrigerators and Refrigerator-Freezers with manual defrost | 16.3 AV 316 |
| Refrigerator-Freezers—partial automatic defrost | 21.8 AV 429 |
| Refrigerator-Freezers—automatic defrost with: | |
| Top mounted freezer without ice | 23.5 AV 471 |
| Side mounted freezer without ice | 27.7 AV 488 |
| Bottom mounted freezer without ice | 27.7 AV 488 |
| Top mounted freezer with through the door ice service | 26.4 AV 535 |
| Side mounted freezer with through the door ice | 30.9 AV 547 |
| Upright Freezers with: | |
| Manual defrost | 10.9 AV 422 |
| Automatic defrost | 16.0 AV 623 |
| Chest Freezers and all other freezers | 14.8 AV 223 |
| Product Class: | Ratio |
|---|---|
| Without Reverse Cycle and With Louvered Sides: | |
| Less than 6,000 Btu | 8.0 |
| 6,000 to 7,999 Btu | 8.5 |
| 8,000 to 13,999 Btu | 9.0 |
| 14,000 to 19,999 Btu | 8.8 |
| 20,000 and more Btu | 8.2 |
| Without Reverse Cycle and Without Louvered Sides: | |
| Less than 6,000 Btu | 8.0 |
| 6,000 to 7,999 Btu | 8.5 |
| 8,000 to 13,999 Btu | 8.5 |
| 14,000 to 19,999 Btu | 8.5 |
| 20,000 and more Btu | 8.2 |
| With Reverse Cycle and With Louvered Sides | 8.5 |
| With Reverse Cycle, Without Louvered Sides | 8.0 |
| (A) Gas Water Heater: | .62(.0019 x Rated Storage Volume in gallons) |
| (B) Oil Water Heater: | .59(.0019 x Rated Storage Volume in gallons) |
| (C) Electric Water Heater: | .95(.00132 x Rated Storage Volume in gallons) |
| Wall | |
| Fan type | |
| Up to 42,000 Btu/hour | 73% AFUE |
| Over 42,000 Btu/hour | 74% AFUE |
| Gravity type | |
| Up to 10,000 Btu/hour | 59% AFUE |
| Over 10,000 Btu/hour up to 12,000 Btu/hour | 60% AFUE |
| Over 12,000 Btu/hour up to 15,000 Btu/hour | 61% AFUE |
| Over 15,000 Btu/hour up to 19,000 Btu/hour | 62% AFUE |
| Over 19,000 Btu/hour up to 27,000 Btu/hour | 63% AFUE |
| Over 27,000 Btu/hour up to 46,000 Btu/hour | 64% AFUE |
| Over 46,000 Btu/hour | 65% AFUE |
| Floor | |
| Up to 37,000 Btu/hour | 56% AFUE |
| Over 37,000 Btu/hour | 57% AFUE |
| Room | |
| Up to 18,000 Btu/hour | 57% AFUE |
| Over 18,000 Btu/hour up to 20,000 Btu/hour | 58% AFUE |
| Over 20,000 Btu/hour up to 27,000 Btu/hour | 63% AFUE |
| Over 27,000 Btu/hour up to 46,000 Btu/hour | 64% AFUE |
| Over 46,000 Btu/hour | 65% AFUE |
| Boiler Type | Minimum Annual Fuel Utilization Efficiency | Design Requirements |
|---|---|---|
| Gas Hot Water | 82% | No Constant Burning Pilot, Automatic Means for Adjusting Water Temperature |
| Gas Steam | 80% | No Constant Burning Pilot |
| Oil Hot Water | 84% | Automatic Means for Adjusting Temperature |
| Oil Steam | 82% | None |
| Electric Hot Water | None | Automatic Means for Adjusting Temperature |
| Electric Steam | None | None |
| Application for Operation of | Ballast Input Voltage | Total Nominal Lamp Watts | Ballast Efficacy Factor |
|---|---|---|---|
| one F40T12 lamp | 120 | 40 | 1.805 |
| 277 | 40 | 1.805 | |
| two F40T12 lamps | 120 | 80 | 1.060 |
| 277 | 80 | 1.050 | |
| two F96T12 lamps | 120 | 150 | 0.570 |
| 277 | 150 | 0.570 | |
| two F96T12HO lamps | 120 | 220 | 0.390 |
| 277 | 220 | 0.390 |
| Application for operation of | Ballast input voltage | Total nominal lamp watts | Ballast efficacy factor |
|---|---|---|---|
| One F34T12 lamp | 120/277 | 34 | 2.61 |
| Two F34T12 lamps | 120/277 | 68 | 1.35 |
| Two F96T12/ES lamps | 120/277 | 120 | 0.77 |
| Two F96T12HO/ES lamps | 120/277 | 190 | 0.42. |
| Lamp Type | Nominal Lamp Wattage | Minimum CRI | Minimum Average Lamp Efficacy (LPW) | Effective Date (Period of Months) |
|---|---|---|---|---|
| 4-foot medium bi-pin | 35 W | 69 | 75.0 | 36 |
| 35 W | 45 | 75.0 | 36 | |
| 2-foot U-shaped | 35 W | 69 | 68.0 | 36 |
| 35 W | 45 | 64.0 | 36 | |
| 8-foot slimline | 65 W | 69 | 80.0 | 18 |
| 65 W | 45 | 80.0 | 18 | |
| 8-foot high output | 100 W | 69 | 80.0 | 18 |
| 100 W | 45 | 80.0 | 18 |
| Nominal Lamp Wattage | Minimum Average Lamp Efficacy (LPW) | Effective Date (Period of Months) |
|---|---|---|
| 40–50 | 10.5 | 36 |
| 51–66 | 11.0 | 36 |
| 67–85 | 12.5 | 36 |
| 86–115 | 14.0 | 36 |
| 116–155 | 14.5 | 36 |
| 156–205 | 15.0 | 36 |
| Lavatory faucets | 2.5 gallons per minute |
| Lavatory replacement aerators | 2.5 gallons per minute |
| Kitchen faucets | 2.5 gallons per minute |
| Kitchen replacement aerators | 2.5 gallons per minute |
| Metering faucets | 0.25 gallons per cycle |
| Active Mode | Nameplate Output | Required Efficiency (decimal equivalent of a percentage) |
|---|---|---|
| Less than 1 watt | 0.5 times the Nameplate Output | |
| From 1 watt to not more than 51 watts | The sum of 0.09 times the Natural Logarithm of the Nameplate Output and 0.5 | |
| Greater than 51 watts | 0.85 | |
| 1 | ||
| No-Load Mode0 | ||
| Nameplate Output | Maximum Consumption | |
| Not more than 250 watts | 0.5 watts |
| Product Capacity (pints/day): | Minimum Energy Factor (liters/kWh) |
| Up to 35.00 | 1.35 |
| 35.01–45.00 | 1.50 |
| 45.01–54.00 | 1.60 |
| 54.01–75.00 | 1.70 |
| Greater than 75.00 | 2.5. |
[1] So in original. Probably should be “is”.
[2] See References in Text note below.
[3] So in original. The word “lamps” probably should appear after “fluorescent”.
[4] So in original. Subpar. (G) does not contain a cl. (i)(II).
[5] So in original. Probably should be “subparagraph (A)(i)”.
| Energy Standards Equations | |
|---|---|
| Refrigerators and Refrigerator-Freezers with manual defrost | 16.3 AV 316 |
| Refrigerator-Freezers—partial automatic defrost | 21.8 AV 429 |
| Refrigerator-Freezers—automatic defrost with: | |
| Top mounted freezer without ice | 23.5 AV 471 |
| Side mounted freezer without ice | 27.7 AV 488 |
| Bottom mounted freezer without ice | 27.7 AV 488 |
| Top mounted freezer with through the door ice service | 26.4 AV 535 |
| Side mounted freezer with through the door ice | 30.9 AV 547 |
| Upright Freezers with: | |
| Manual defrost | 10.9 AV 422 |
| Automatic defrost | 16.0 AV 623 |
| Chest Freezers and all other freezers | 14.8 AV 223 |
| Product Class: | Ratio |
|---|---|
| Without Reverse Cycle and With Louvered Sides: | |
| Less than 6,000 Btu | 8.0 |
| 6,000 to 7,999 Btu | 8.5 |
| 8,000 to 13,999 Btu | 9.0 |
| 14,000 to 19,999 Btu | 8.8 |
| 20,000 and more Btu | 8.2 |
| Without Reverse Cycle and Without Louvered Sides: | |
| Less than 6,000 Btu | 8.0 |
| 6,000 to 7,999 Btu | 8.5 |
| 8,000 to 13,999 Btu | 8.5 |
| 14,000 to 19,999 Btu | 8.5 |
| 20,000 and more Btu | 8.2 |
| With Reverse Cycle and With Louvered Sides | 8.5 |
| With Reverse Cycle, Without Louvered Sides | 8.0 |
| (A) Gas Water Heater: | .62(.0019 x Rated Storage Volume in gallons) |
| (B) Oil Water Heater: | .59(.0019 x Rated Storage Volume in gallons) |
| (C) Electric Water Heater: | .95(.00132 x Rated Storage Volume in gallons) |
| Wall | |
| Fan type | |
| Up to 42,000 Btu/hour | 73% AFUE |
| Over 42,000 Btu/hour | 74% AFUE |
| Gravity type | |
| Up to 10,000 Btu/hour | 59% AFUE |
| Over 10,000 Btu/hour up to 12,000 Btu/hour | 60% AFUE |
| Over 12,000 Btu/hour up to 15,000 Btu/hour | 61% AFUE |
| Over 15,000 Btu/hour up to 19,000 Btu/hour | 62% AFUE |
| Over 19,000 Btu/hour up to 27,000 Btu/hour | 63% AFUE |
| Over 27,000 Btu/hour up to 46,000 Btu/hour | 64% AFUE |
| Over 46,000 Btu/hour | 65% AFUE |
| Floor | |
| Up to 37,000 Btu/hour | 56% AFUE |
| Over 37,000 Btu/hour | 57% AFUE |
| Room | |
| Up to 18,000 Btu/hour | 57% AFUE |
| Over 18,000 Btu/hour up to 20,000 Btu/hour | 58% AFUE |
| Over 20,000 Btu/hour up to 27,000 Btu/hour | 63% AFUE |
| Over 27,000 Btu/hour up to 46,000 Btu/hour | 64% AFUE |
| Over 46,000 Btu/hour | 65% AFUE |
| Boiler Type | Minimum Annual Fuel Utilization Efficiency | Design Requirements |
|---|---|---|
| Gas Hot Water | 82% | No Constant Burning Pilot, Automatic Means for Adjusting Water Temperature |
| Gas Steam | 80% | No Constant Burning Pilot |
| Oil Hot Water | 84% | Automatic Means for Adjusting Temperature |
| Oil Steam | 82% | None |
| Electric Hot Water | None | Automatic Means for Adjusting Temperature |
| Electric Steam | None | None |
| Application for Operation of | Ballast Input Voltage | Total Nominal Lamp Watts | Ballast Efficacy Factor |
|---|---|---|---|
| one F40T12 lamp | 120 | 40 | 1.805 |
| 277 | 40 | 1.805 | |
| two F40T12 lamps | 120 | 80 | 1.060 |
| 277 | 80 | 1.050 | |
| two F96T12 lamps | 120 | 150 | 0.570 |
| 277 | 150 | 0.570 | |
| two F96T12HO lamps | 120 | 220 | 0.390 |
| 277 | 220 | 0.390 |
| Application for operation of | Ballast input voltage | Total nominal lamp watts | Ballast efficacy factor |
|---|---|---|---|
| One F34T12 lamp | 120/277 | 34 | 2.61 |
| Two F34T12 lamps | 120/277 | 68 | 1.35 |
| Two F96T12/ES lamps | 120/277 | 120 | 0.77 |
| Two F96T12HO/ES lamps | 120/277 | 190 | 0.42. |
| Lamp Type | Nominal Lamp Wattage | Minimum CRI | Minimum Average Lamp Efficacy (LPW) | Effective Date (Period of Months) |
|---|---|---|---|---|
| 4-foot medium bi-pin | 35 W | 69 | 75.0 | 36 |
| 35 W | 45 | 75.0 | 36 | |
| 2-foot U-shaped | 35 W | 69 | 68.0 | 36 |
| 35 W | 45 | 64.0 | 36 | |
| 8-foot slimline | 65 W | 69 | 80.0 | 18 |
| 65 W | 45 | 80.0 | 18 | |
| 8-foot high output | 100 W | 69 | 80.0 | 18 |
| 100 W | 45 | 80.0 | 18 |
| Nominal Lamp Wattage | Minimum Average Lamp Efficacy (LPW) | Effective Date (Period of Months) |
|---|---|---|
| 40–50 | 10.5 | 36 |
| 51–66 | 11.0 | 36 |
| 67–85 | 12.5 | 36 |
| 86–115 | 14.0 | 36 |
| 116–155 | 14.5 | 36 |
| 156–205 | 15.0 | 36 |
| Lavatory faucets | 2.5 gallons per minute |
| Lavatory replacement aerators | 2.5 gallons per minute |
| Kitchen faucets | 2.5 gallons per minute |
| Kitchen replacement aerators | 2.5 gallons per minute |
| Metering faucets | 0.25 gallons per cycle |
| Active Mode | Nameplate Output | Required Efficiency (decimal equivalent of a percentage) |
|---|---|---|
| Less than 1 watt | 0.5 times the Nameplate Output | |
| From 1 watt to not more than 51 watts | The sum of 0.09 times the Natural Logarithm of the Nameplate Output and 0.5 | |
| Greater than 51 watts | 0.85 | |
| 1 | ||
| No-Load Mode0 | ||
| Nameplate Output | Maximum Consumption | |
| Not more than 250 watts | 0.5 watts |
| Product Capacity (pints/day): | Minimum Energy Factor (liters/kWh) |
| Up to 35.00 | 1.35 |
| 35.01–45.00 | 1.50 |
| 45.01–54.00 | 1.60 |
| 54.01–75.00 | 1.70 |
| Greater than 75.00 | 2.5. |
[1] See References in Text note below.
[2] So in original. The word “lamps” probably should appear after “fluorescent”.
[3] So in original. Subpar. (G) does not contain a cl. (i)(II).
[4] So in original. Probably should be “subparagraph (A)(i)”.
[5] So in original. Probably should be “(4)”.
The table below lists the classification updates, since Jan. 3, 2012, for this section. Updates to a broader range of sections may be found at the update page for containing chapter, title, etc.
The most recent Classification Table update that we have noticed was Wednesday, February 6, 2013
An empty table indicates that we see no relevant changes listed in the classification tables. If you suspect that our system may be missing something, please double-check with the Office of the Law Revision Counsel.
| 42 USC | Description of Change | Session Year | Public Law | Statutes at Large |
|---|---|---|---|---|
| § 6295 | 2012 | 112-210 [Sec.] 10(a)(11) | 126 Stat. 1525 | |
| § 6295 | nt new | 2012 | 112-210 [Sec.] 10(b)(2) | 126 Stat. 1525 |
| § 6295 | 2012 | 112-210 [Sec.] 10(b)(1) | 126 Stat. 1525 | |
| § 6295 | 2012 | 112-210 [Sec.] 10(a)(8) | 126 Stat. 1524 | |
| § 6295 | 2012 | 112-210 [Sec.] 10(a)(1) | 126 Stat. 1522 | |
| § 6295 | 2012 | 112-210 [Sec.] 5(c) | 126 Stat. 1519 | |
| § 6295 | 2012 | 112-210 [Sec.] 5(a) | 126 Stat. 1517 | |
| § 6295 | 2012 | 112-210 [Sec.] 3 | 126 Stat. 1514 |
This is a list of parts within the Code of Federal Regulations for which this US Code section provides rulemaking authority.
This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].
It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.