14 CFR 23.1095 - Carburetor deicing fluid flow rate.

Beta! The text on the eCFR tab represents the unofficial eCFR text at ecfr.gov.
§ 23.1095 Carburetor deicing fluid flow rate.

(a) If a carburetor deicing fluid system is used, it must be able to simultaneously supply each engine with a rate of fluid flow, expressed in pounds per hour, of not less than 2.5 times the square root of the maximum continuous power of the engine.

(b) The fluid must be introduced into the air induction system -

(1) Close to, and upstream of, the carburetor; and

(2) So that it is equally distributed over the entire cross section of the induction system air passages.

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.


United States Code

Title 14 published on 2015-01-01

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 14 CFR Part 23 after this date.

  • 2015-12-09; vol. 80 # 236 - Wednesday, December 9, 2015
    1. 80 FR 76379 - Special Conditions: Cirrus Aircraft Corporation, SF50; Auto Throttle
      GPO FDSys XML | Text
      DEPARTMENT OF TRANSPORTATION, Federal Aviation Administration
      Final special conditions.
      The effective date of these special conditions is December 9, 2015 and are applicable on December 2, 2015.
      14 CFR Part 23