14 CFR 23.1393 - Minimum intensities in any vertical plane of position lights.

§ 23.1393 Minimum intensities in any vertical plane of position lights.

Each position light intensity must equal or exceed the applicable values in the following table:

Angle above or below the horizontal plane Intensity, l
1.00
0° to 5° 0.90
5° to 10° 0.80
10° to 15° 0.70
15° to 20° 0.50
20° to 30° 0.30
30° to 40° 0.10
40° to 90° 0.05
[Doc. No. 4080, 29 FR 17955, Dec. 18, 1964, as amended by Amdt. 23-43, 58 FR 18977, Apr. 9, 1993]

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.