14 CFR 23.1393 - Minimum intensities in any vertical plane of position lights.

Beta! The text on the eCFR tab represents the unofficial eCFR text at ecfr.gov.
§ 23.1393 Minimum intensities in any vertical plane of position lights.

Each position light intensity must equal or exceed the applicable values in the following table:

Angle above or below the horizontal plane Intensity, l
1.00
0° to 5° 0.90
5° to 10° 0.80
10° to 15° 0.70
15° to 20° 0.50
20° to 30° 0.30
30° to 40° 0.10
40° to 90° 0.05
[Doc. No. 4080, 29 FR 17955, Dec. 18, 1964, as amended by Amdt. 23-43, 58 FR 18977, Apr. 9, 1993]