§ 57.6602 Static electricity dissipation during loading.

When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard -

(a) An evaluation of the potential static electricity hazard shall be made and any hazard shall be eliminated before loading begins;

(b) The loading hose shall be of a semiconductive type, have a total of not more than 2 megohms of resistance over its entire length and not less than 1000 ohms of resistance per foot;

(c) Wire-countered hoses shall not be used;

(d) Conductive parts of the loading equipment shall be bonded and grounded and grounds shall not be made to other potential sources of extraneous electricity; and

(e) Plastic tubes shall not be used as hole liners if the hole contains an electric detonator.

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.

United States Code

Title 30 published on 2015-07-01

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 30 CFR Part 57 after this date.

  • 2015-09-02; vol. 80 # 170 - Wednesday, September 2, 2015
    1. 80 FR 52984 - MSHA Headquarters, Pittsburgh Safety and Health Technology Center, and Respirable Dust Processing Laboratory Address Changes
      GPO FDSys XML | Text
      DEPARTMENT OF LABOR, Mine Safety and Health Administration
      Final rule; technical amendment.
      Effective Date: September 2, 2015.
      30 CFR Parts 7, 18, 44, 46, 48, 49, 56, 57, 70, 71, 72, 74, 75, and 90