1. Organics:
Dioxins/Furans (total mass basis) 125 nanorgrams per dry standard cubic meter 3-run average (minimum run duration is 4 hours) Stack test.
2. Metals:
Cadmium 0.10 milligrams per dry standard cubic meter 3-run average (run duration specified in test method) Stack test.
Lead 1.6 milligrams per dry standard cubic meter 3-run average (run duration specified in test method) Stack test.
Mercury 0.080 milligrams per dry standard cubic meter 3-run average (run duration specified in test method) Stack test.
85 percent reduction of potential mercury emissions
Opacity 10 percent Thirty 6-minute average Stack test.
Particulate Matter 70 milligrams per dry standard cubic meter 3-run average (run duration specified in test method) Stack test.
3. Acid Gases:
Hydrogen Chloride 250 parts per million by volume -or- 3-run average (minimum run duration is 1 hour) Stack test.
50 percent reduction of potential hydrogen chloride emissions
Sulfur Dioxide 77 parts per million by dry volume -or-
50 percent reduction of potential sulfur dioxides emissions
24-hour daily block geometric average concentration -or- percent reduction Continuous emission monitoring system.
4. Other:
Fugitive Ash Visible emissions for no more than 5 percent of hourly observation period Three 1-hour observation periods Visible emission test.

a Class II units mean all small municipal combustion units subject to this subpart that are located at municipal waste combustion plants with aggregate plant combustion capacity less than or equal to 250 tons per day of municipal solid waste. See § 60.1940 for definitions.

b All emission limits (except for opacity) are measured at 7 percent oxygen.