40 CFR Appendix Table 2 to Subpart Cb of Part 60 - Table 2 to Subpart Cb of Part 60—Nitrogen Oxides Limits for Existing Designated Facilities Included in an Emissions Averaging Plan at a Municipal Waste Combustor Plant b

Table 2 to Subpart Cb of Part 60—Nitrogen Oxides Limits for Existing Designated Facilities Included in an Emissions Averaging Plan at a Municipal Waste Combustor Plant b
Municipal waste combustor technology Before April 28, 2009,
nitrogen oxides emission limit
(parts per million by volume) b
On and after April 28, 2009,
nitrogen oxides emission limit
(parts per million by volume) a
Mass burn waterwall 185 185
Mass burn rotary waterwall 220 190
Refuse-derived fuel combustor 230 230
Fluidized bed combustor 165 165

a Mass burn refractory municipal waste combustors and other MWC technologies not listed above may not be included in an emissions averaging plan.

b Corrected to 7 percent oxygen, dry basis.

[71 FR 27334, May 10, 2006]