As required in § 63.9950, you must comply with the requirements of the NESHAP General Provisions (40 CFR part 63, subpart A) shown in the following table:
Citation | Subject | Applies to Subpart
TTTTT |
Explanation |
---|---|---|---|
63.1 | Applicability | Yes. | |
63.2 | Definitions | Yes. | |
63.3 | Units and Abbreviations | Yes. | |
63.4 | Prohibited Activities | Yes. | |
63.5 | Construction and Reconstruction | Yes. | |
63.6(a)–(g) | Compliance with Standards and Maintenance Requirements | Yes. | |
63.6(h) | Determining Compliance with Opacity and Visible Emission Standards | No. | |
63.6(i)–(j) | Extension of Compliance and Presidential Compliance Exemption | Yes. | |
63.7(a)(1)–(2) | Applicability and Performance Test Dates | No | Subpart TTTTT specifies performance test applicability and dates. |
63.7(a)(3), (b)–(h) | Performance Testing Requirements | Yes. | |
63.8 except for (a)(4),(c)(4), and (f)(6) | Monitoring Requirements | Yes. | |
63.8(a)(4) | Additional Monitoring Requirements for Control Devices in § 63.11 | No | Subpart TTTTT does not require flares. |
63.8(c)(4) | Continuous Monitoring System Requirements | No | Subpart TTTTT specifies requirements for operation of CMS. |
63.8(f)(6) | Relative Accuracy Test Alternative (RATA) | No | Subpart TTTTT does not require continuous emission monitoring systems. |
63.9 | Notification Requirements | Yes. | |
63.9(g)(5) | Data Reduction | No | Subpart TTTTT specifies data reduction requirements. |
63.10 except for (b)(2)(xiii) and (c)(7)–(8) | Recordkeeping and Reporting Requirements | Yes. | |
63.10(b)(2)(xiii) | Continuous Monitoring System (CMS) Records for RATA Alternative | No | Subpart TTTTT does not require continuous emission monitoring systems. |
63.10(c)(7)–(8) | Records of Excess Emissions and Parameter Monitoring Accedences for CMS | No | Subpart TTTTT specifies recordkeeping requirements. |
63.11 | Control Device Requirements | No | Subpart TTTTT does not require flares. |
63.12 | State Authority and Delegations | Yes. | |
63.13–63.15 | Addresses, Incorporation by Reference, Availability of Information | Yes. |