40 CFR Appendix Table 1 to Subpart YYYY of Part 63 - Table 1 to Subpart YYYY of Part 63—Emission Limitations

Table 1 to Subpart YYYY of Part 63—Emission Limitations

As stated in § 63.6100, you must comply with the following emission limitations.

For each new or reconstructed stationary combustion turbine described in § 63.6100 which is . . . You must meet the following emission limitations . . .
1. a lean premix gas-fired stationary combustion turbine as defined in this subpart,
2. a lean premix oil-fired stationary combustion turbine as defined in this subpart,
3. a diffusion flame gas-fired stationary combustion turbine as defined in this subpart, or
4. a diffusion flame oil-fired stationary combustion turbine as defined in this subpart.
limit the concentration of formaldehyde to 91 ppbvd or less at 15-percent O2, except during turbine startup. The period of time for turbine startup is subject to the limits specified in the definition of startup in § 63.6175.
[85 FR 13542, Mar. 9, 2020]