Clothes dryers.

Clothes dryers.
(1) Gas clothes dryers manufactured after January 1, 1988 shall not be equipped with a constant burning pilot.
(2) Clothes dryers manufactured on or after May 14, 1994 and before January 1, 2015, shall have an energy factor no less than:
(3) Clothes dryers manufactured on or after January 1, 2015, shall have a combined energy factor no less than:
(1) Gas clothes dryers manufactured after January 1, 1988 shall not be equipped with a constant burning pilot.
(2) Clothes dryers manufactured on or after May 14, 1994 and before January 1, 2015, shall have an energy factor no less than:
(3) Clothes dryers manufactured on or after January 1, 2015, shall have a combined energy factor no less than:
(i) Direct heating equipment.
(1) Vented home heating equipment manufactured on or after January 1, 1990 and before April 16, 2013, shall have an annual fuel utilization efficiency no less than:
(2) Vented home heating equipment manufactured on or after April 16, 2013, shall have an annual fuel utilization efficiency no less than:
(j) Cooking Products (1) Gas cooking products with an electrical supply cord manufactured on or after January 1, 1990, shall not be equipped with a constant burning pilot light.
(2) Gas cooking products without an electrical supply cord manufactured on or after April 9, 2012, shall not be equipped with a constant burning pilot light.
(3) Microwave-only ovens and countertop convection microwave ovens manufactured on or after June 17, 2016 shall have an average standby power not more than 1.0 watt. Built-in and over-the-range convection microwave ovens manufactured on or after June 17, 2016 shall have an average standby power not more than 2.2 watts.
(k) Pool heaters.
(1) Gas-fired pool heaters manufactured on or after January 1, 1990 and before April 16, 2013, shall have a thermal efficiency not less than 78%.
(2) Gas-fired pool heaters manufactured on or after April 16, 2013, shall have a thermal efficiency not less than 82%.
(l) Television sets. [Reserved]
(m) Fluorescent lamp ballasts—(1) Standards for fluorescent lamp ballasts (other than dimming ballasts). Except as provided in paragraphs (m)(2) and (3) of this section, each fluorescent lamp ballast manufactured on or after November 14, 2014,
(i) Designed and marketed—
(A) To operate at nominal input voltages at or between 120 and 277 volts;
(B) To operate with an input current frequency of 60 Hertz; and
(C) For use in connection with fluorescent lamps (as defined in § 430.2)
(ii) Must have—
(A) A power factor of:
(1) 0.9 or greater for ballasts that are not residential ballasts; or
(2) 0.5 or greater for residential ballasts; and
(B) A ballast luminous efficiency not less than the following:
(2) Standards for certain dimming ballasts. Except as provided in paragraph (m)(3) of this section, each dimming ballast manufactured on or after November 14, 2014; designed and marketed to operate one F34T12, two F34T12, two F96T12/ES, or two F96T12HO/ES lamps; and
(i) Designed and marketed—
(A) To operate at nominal input voltages at or between 120 and 277 volts;
(B) To operate with an input current frequency of 60 Hertz; and
(C) For use in connection with fluorescent lamps (as defined in § 430.2)
(ii) Must have—
(A) A power factor of:
(1) 0.9 or greater for ballasts that are not residential ballasts; or
(2) 0.5 or greater for residential ballasts; and
(B) A ballast luminous efficiency not less than the following:
(3) Exemptions. The power factor and ballast luminous efficiency standards described in paragraph (m)(1)(ii) and (m)(2)(ii) of this section do not apply to:
(i) A dimming ballast designed and marketed to operate exclusively lamp types other than one F34T12, two F34T12, two F96T12/ES, or two F96T12HO/ES lamps;
(ii) A low frequency ballast that is designed and marketed to operate T8 diameter lamps; is designed and marketed for use in electromagnetic-interference-sensitive-environments only; and is shipped by the manufacturer in packages containing 10 or fewer ballasts; or
(iii) A programmed start ballast that operates 4-foot medium bipin T8 lamps and delivers on average less than 140 milliamperes to each lamp.
(4) For the purposes of this paragraph (m), the definitions found in appendix Q of subpart B of this part apply.
(n) General service fluorescent lamps and incandescent reflector lamps.
(1) Each of the following general service fluorescent lamps manufactured after the effective dates specified in the table must meet or exceed the following color rendering index standards:

Source

10 CFR § 430.32