Electronic

(i) Electronic. Unit operating and capacity factor information demonstrating that the unit qualifies as a peaking unit or gas-fired unit, as defined in 72.2 of this chapter, and NOX correlation test information, including: (A) Test date; (B) Test number; (C) Operating level; (D) Segment ID of the NOX correlation curve; (E) NOX monitoring system identification; (F) Low and high heat input rate values and corresponding NOX emission rates; (G) Type of fuel; and (H) To document the unit qualifies as a peaking unit, current calendar year or ozone season, capacity factor data as specified in the definition of peaking unit in 72.2 of this chapter, and an indication of whether the data are actual or projected data. (ii) Hardcopy. (A) A protocol containing methods used to perform the baseline or periodic NOX emission test; and (B) Unit operating parameters related to NOX formation by the unit. (3) For each gas-fired unit and diesel-fired unit or unit with a wet flue gas pollution control system for which the designated representative claims an opacity monitoring exemption under 75.14, the designated representative shall include in the hardcopy monitoring plan the information specified under 75.14(b), (c), or (d), demonstrating that the unit qualifies for the exemption. (4) For each monitoring system recertification, maintenance, or other event, the designated representative shall include the following additional information in electronic format in the monitoring plan: (i) Component/system identification code; (ii) Event code or code for required test; (iii) Event begin date and hour; (iv) Conditionally valid data period begin date and hour (if applicable); (v) Date and hour that last test is successfully completed; and (vi) Indicator of whether conditionally valid data were reported at the end of the quarter. (5) For each unit using the low mass emission excepted methodology under 75.19 the designated representative shall include the following additional information in the monitoring plan that accompanies the initial certification application: (i) Electronic. For each low mass emissions unit, report the results of the analysis performed to qualify as a low mass emissions unit under 75.19(c). This report will include either the previous three years actual or projected emissions. The following items should be included: (A) Current calendar year of application; (B) Type of qualification; (C) Years one, two, and three; (D) Annual or ozone season measured, estimated or projected NOX mass emissions for years one, two, and three; (E) Annual measured, estimated or projected SO2 mass emissions for years one, two, and three; and (F) Annual or ozone season operating hours for years one, two, and three. (ii) Hardcopy. (A) A schematic diagram identifying the relationship between the unit, all fuel supply lines and tanks, any fuel flowmeter(s), and the stack(s). Comprehensive and/or separate schematic diagrams shall be used to describe groups of units using a common pipe; (B) For units which use the long term fuel flow methodology under 75.19(c)(3), the designated representative must provide a diagram of the fuel flow to each affected unit or group of units and describe in detail the procedures used to determine the long term fuel flow for a unit or group of units for each fuel combusted by the unit or group of units; (C) A statement that the unit burns only gaseous fuel(s) and/or fuel oil and a list of the fuels that are burned or a statement that the unit is projected to burn only gaseous fuel(s) and/or fuel oil and a list of the fuels that are projected to be burned; (D) A statement that the unit meets the applicability requirements in 75.19(a) and (b); and (E) Any unit historical actual, estimated and projected emissions data and calculated emissions data demonstrating that the affected unit qualifies as a low mass emissions unit under 75.19(a) and 75.19(b). (6) For each gas-fired unit the designated representative shall include in the monitoring plan, in electronic format, the following: current calendar year, fuel usage data as specified in the definition of gas-fired in 72.2 of this part, and an indication of whether the data are actual or projected data.

Source

40 CFR § 75.53


Scoping language

None
Is this correct? or