Optional adjuvant substances.

Optional adjuvant substances. The perfluorocarbon cured elastomer identified in paragraph (a) of this section may contain the following optional adjuvant substances, subject to any limitations cited on their use:
(1) Substances generally recognized as safe (GRAS) in food or food packaging.
(2) Substances used in accordance with a prior sanction.
(3) Substances authorized under applicable regulations in this part and in parts 175 and 178 of this chapter and subject to any limitations prescribed therein.
(4) Substances identified in this paragraph (b)(4) subject to such limitations as are provided:
(1) Substances generally recognized as safe (GRAS) in food or food packaging.
(2) Substances used in accordance with a prior sanction.
(3) Substances authorized under applicable regulations in this part and in parts 175 and 178 of this chapter and subject to any limitations prescribed therein.
(4) Substances identified in this paragraph (b)(4) subject to such limitations as are provided:
(c) Specifications—(1) Infrared identification. Perfluorocarbon cured elastomers may be identified by the characteristic infrared spectra of the pyrolysate breakdown product that is obtained by heating and decomposing the elastomer using the method entitled “Qualitative Identification of Kalrez ® by Infrared Examination of Pyrolysate.” This method is incorporated by reference. Copies of the method are available from the Center for Food Safety and Applied Nutrition (HFS–200), Food and Drug Administration, 5001 Campus Dr., College Park, MD 20740, or available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202–741–6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
(2) Thermogravimetry. Perfluorocarbon cured elastomers have a major decomposition peak occurring at 490° ±15 °C (914 °F). Less than 1.5 percent of the elastomers will volatilize below 400 °C (752 °F) when run under nitrogen at a 10 °C or 18 °F per minute heating rate using a Du Pont Thermal Analyzer Model 1099 with Model 951 TGA unit or the equivalent.
(d) Extractive limitations. Articles fabricated from perfluorocarbon cured elastomers having a thickness of at least 1.0 millimeter (0.039 inch) when extracted at reflux temperatures for 2 hours separately with distilled water, 50 percent ethanol, and n-heptane, shall meet the following extractability limits:
(1) Total extractives not to exceed 3.1 milligrams per square decimeter (0.2 milligrams per square inch).
(2) Fluoride extractives calculated as fluorine not to exceed 0.47 milligram per square decimeter (0.03 milligram per square inch).
(e) Conditions of use. In accordance with current good manufacturing practice, finished food contact articles containing the perfluorocarbon cured elastomers shall be thoroughly cleaned prior to their first use in contact with food.