Annualizing Method

(1) Annualizing Method(i) Step 1. Take the number of pounds of refrigerant added to the appliance to return it to a full charge, whether in one addition or in multiple additions related to same leak, and divide it by the number of pounds of refrigerant the appliance normally contains at full charge; (ii) Step 2. Take the shorter of the number of days that have passed since the last day refrigerant was added or 365 days and divide that number by 365 days; (iii) Step 3. Take the number calculated in Step 1 and divide it by the number calculated in Step 2; and (iv) Step 4. Multiply the number calculated in Step 3 by 100 to calculate a percentage. This method is summarized in the following formula: (2) Rolling Average Method(i) Step 1. Take the sum of the pounds of refrigerant added to the appliance over the previous 365-day period (or over the period that has passed since the last successful follow-up verification test showing all identified leaks in the appliance were repaired, if that period is less than one year); (ii) Step 2. Divide the result of Step 1 by the pounds of refrigerant the appliance normally contains at full charge; and (iii) Step 3. Multiply the result of Step 2 by 100 to obtain a percentage. This method is summarized in the following formula:

Source

40 CFR § 84.102