Other control devices.

Other control devices. For each control device other than a baghouse or venturi wet scrubber subject to the operating limits for site-specific operating parameters in 63.1444(h) or 63.1446(e), you must demonstrate continuous compliance by meeting the requirements of paragraphs (e)(1) through (3) of this section:
(1) Maintain the hourly average rate at levels no lower than those established during the initial or subsequent performance test;
(2) Inspect and maintain each CPMS operated according to § 63.1452(d) and record all information needed to document conformance with these requirements; and
(3) Collect and reduce monitoring data for selected parameters according to § 63.1452(e) and recording all information needed to document conformance with these requirements.