Ala. Admin. Code r. 335-13-4-.11 - General Design Standards For Disposal Facilities
(1)
General
Standards.
335-13-4-.12 through
335-13-4-.20 provides standards
for establishing a landfill unit providing that the siting standards of
335-13-4-.01 have been fully
complied with to the satisfaction of the Department. Certain requirements
contained in
335-13-4-.01 through
335-13-4-.20 may be enhanced or
reduced by the Department as deemed necessary to comply with the Act and this
Division.
(2)
Hydrogeology Standards.
(a) For purposes of designing the bottom
elevation of the proposed cell, the applicant shall measure the groundwater
elevation at the location of the proposed cell or liner system. Such
determinations shall be based on groundwater measurements taken in the area of
the proposed cell or liner system as approved by the Department. At each
measuring location, the applicant shall obtain a minimum of two measurements
taken during each of the three consecutive months of February, March and April,
or as otherwise approved by the Department, with no two measurements taken
within any twelve-day period. Having obtained the measurements, the applicant
shall design the facility so that the bottom elevation of the proposed cell or
liner system shall be a minimum of five feet above the highest measured
groundwater level. The applicant shall submit to the Department all data known
to exist concerning groundwater elevations at the landfill site and shall
submit to the Department a location map showing all monitoring wells or
piezometers and drilling logs for all monitoring wells or piezometers used to
obtain any groundwater elevation data that is submitted. Nothing herein shall
prevent the Department from requiring additional groundwater measurements or
from requiring an additional buffer as it may deem appropriate with respect to
a particular site.
(b) When the
geological and hydrological data so indicate, the Department may specify
greater separation distances, a liner(s), or a leachate collection system, or
combination of the above to protect the groundwater.
(c) When the geological and hydrological data
so indicate, the Department may allow engineering controls to remove, divert,
drain, or otherwise modify zones of saturation above the uppermost
aquifer.
Notes
Authors: Russell A. Kelly, S. Scott Story
Statutory Authority: Code of Ala. 1975, ยงยง 22-27-3, 22-27-7.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.