(1)No person
shall cause or permit to be emitted into the open air from any incinerator
which incinerates wood, peanut, or cotton ginning wastes, particulate matter in
the exhaust gases to exceed 0.40 pounds per 100 pounds of materials
charged.
(2)Emission tests shall be
conducted at maximum burning capacity of the incinerator.
(3)The burning capacity of an incinerator
shall be the manufacturer's or designer's guaranteed maximum rate or such other
rate as may be determined by the Director in accordance with good engineering
practices. In case of conflict, the determination made by the Director shall
govern.
(4)Each incinerator subject
to this Rule shall be properly designed, equipped, and maintained for its
maximum burning capacity and shall be equipped with a temperature recorder
which shall be operated continuously with the incinerator; and the temperature
records shall be made available for inspection at the request of the Director
and shall either:
(a)be equipped with an
underfire forced air system, which shall be electronically controlled to insure
that optimum temperature range for the complete combustion of the amount and
type of material waste being charged into the incinerator, and a variable
damper, or
(b)consist of an
all-metal shell with refractory lining, circular furnace, and a built-in cinder
catching system for either reburning or other disposition; all primary
combustion air shall be supplied under pressure through nozzle openings located
around the periphery of the lower furnace; over-fire air shall be provided
under pressure through ports which shall be directed downward and tangentially
in the same direction as the primary air; cinder collection shall be
accomplished by the provision of openings through the shell located above the
furnace section.
(5)Each
incinerator subject to this Rule shall be properly designed, equipped, and
maintained for its maximum rated burning capacity and shall be equipped with an
underfire forced air system, an over-fire air recirculation secondary
combustion system, and variable control damper, all of which shall be
electronically controlled to insure the optimum temperature range for the
complete combustion of the amount and type of material waste being charged into
the incinerator. Each such incinerator shall be equipped with a temperature
recorder which shall be operated continuously with the incinerator, and the
temperature records shall be made available for inspection at the request of
the Director.