Ala. Admin. Code r. 420-3-1-.53 - Gravel Field Standard EDF Sizing For Dwellings
(1) The Gravel Field Standard is the minimum
total trench bottom area for dwellings calculated by multiplying the number of
bedrooms by the number in the column labeled "Square Feet per Bedroom" in Table
2 or Table 3. The loading rate for an EDF shall correspond to the measured or
assigned percolation rate determined according to
420-3-1-.39 Soil
Permeability.
(2) A primary EDF for
dwellings shall be a minimum of 300 square feet of the Gravel Field Standard.
Permitted disposal products may be used with appropriate sizing.
Notes
Previous Rule .79 was renumbered .53 per certification published December 30, 2022; effective February 13, 2023.
Author: Thad Pittman, Matthew Conner, Ken Stephens, Bob Bright
Statutory Authority: Code of Ala. 1975, ยงยง 22-2-2(4); 22-2-2(6); 22-10-1, et seq.; 22-26-1et seq.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.