18 AAC 30.660 - Public showers

(a) Walls in a public shower must be water-impervious up to showerhead height.
(b) Walls and ceilings of a public shower must be smooth and easily cleanable.
(c) Shower and drying areas of a public shower must be constructed with water-impervious, nonskid floors. Floors must slope uniformly at a minimum of one-fourth inch per foot to drains.
(d) Showers and drying areas of a public shower must be ventilated by mechanical exhaust systems.
(e) Showers and drying areas of a public shower must be cleaned and disinfected daily during periods of use.
(f) Towels, if provided, must be laundered between uses and stored in a sanitary manner.
(g) The water temperature for hot water supplied to public showers may not be less than 100 degrees F. nor more than 120 degrees F.

Notes

18 AAC 30.660
Eff. 4/18/82, Register 82

Authority:AS 44.46.020

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.