7 AAC 10.1015 - Heating and heating devices
(a) An entity shall
ensure that room temperature in the facility is maintained at the following
applicable draft-free temperature, adjusted as needed for the majority of
adults or children in care to be comfortable:
(1) 65 degrees Fahrenheit for an entity
licensed to provide care for children;
(2) 68 degrees Fahrenheit for an entity
licensed to provide care for adults.
(b) The entity shall ensure that
(1) each heating device is installed and
maintained in a safe and serviceable manner and is
(A) vented to the outside if the device is
fuel burning; vents or stacks leading from a heating unit must be air-tight at
joints so that fumes, smoke, or unburned gases cannot pass from the device,
vent, or stack into the entity;
(B)
equipped with protective devices if presenting a hazard because of an exposed
flame or heating element; heat sources must be shielded in a manner that
prevents burn injury; the shield must be far enough from the heat source to
prevent it from smoldering or burning; and
(C) not placed or located in sleeping
quarters during sleeping hours, unless the entity does not have a separate
sleeping area, or in exit ways or corridors at any time; and
(2) an open flame heater is not
used, except for a fireplace that complies with 13 AAC 50, 13 AAC 55, and any
applicable municipal building code; if a fireplace is used, it must have a
protective screen or gate, and the area near the fireplace must be kept free of
clutter and combustible or flammable material.
(c) The entity shall ensure that any portable
electric heater is equipped with a tipover switch and is kept out of the reach
of children, or adults with impaired judgment. A portable electric heater must
be kept from flammable objects in accordance with the manufacturer's
recommendations. The entity must develop and implement a policy that outlines
the safe and proper use of portable heaters.
Notes
Authority:AS 18.05.010
AS 18.05.040
AS 44.29.020
AS 47.32.010
AS 47.32.020
AS 47.32.030
AS 47.33.005
AS 47.33.010