8 AAC 61.1030 - Additional respiratory protection standards
In addition to the requirements set out in 29 C.F.R. 1910.134(i) (5), as amended, the employer shall either:
(1) station a
competent employee outside of the work area to monitor and attend the compressor
and other equipment that supplies breathing air; this employee must be trained in
supplied air systems and must receive instruction in the function and maintenance
of the particular supplied air system that is being used at the work site; this
employee must be able to demonstrate the ability to respond appropriately to a
malfunction of the system; or
(2)
employ a compressed air system that includes alarms for compressor failure and
overheating; the system must be equipped with a carbon monoxide alarm; all
compressed air systems must be equipped with in-line adsorbents and filters to
deliver Grade D air; alarms must alert respirator wearers of problems either
remotely or by being loud enough to be heard up to 300 feet away; the monitoring
equipment, alarms, and filters must be checked before use to ensure they are
working properly.