Cal. Code Regs. Tit. 22, div. 4.5, ch. 18, app VI - Recommended Technologies to Achieve Deactivation of Characteristics in Section 66268.42

The treatment standard for many characteristic wastes is stated in the section 66268.40 Table of Treatment Standards as "Deactivation and meet UTS." USEPA has determined that many technologies, when used alone or in combination, can achieve the deactivation portion of the treatment standard. Characteristic wastes that are not managed in a facility regulated by the federal Clean Water Act (CWA) or in a federal CWA-equivalent facility, and that also contain underlying hazardous constituents (see section 66260.10) shall be treated not only by a "deactivating" technology to remove the characteristic, but also to achieve the universal treatment standards (UTS) for underlying hazardous constituents. The following appendix presents a partial list of technologies, utilizing the five letter technology codes established in section 66268.42 Table 1, that may be useful in meeting the treatment standard. Use of these specific technologies is not mandatory and does not preclude direct reuse, recovery, and/or the use of other pretreatment technologies, provided deactivation is achieved and underlying hazardous constituents are treated to achieve the UTS.

Waste Code/Subcategory

Nonwastewaters

Wastewaters

D001 Ignitable Liquids based RORGS n.a.
on 66261.21(a)(1) - Low TOC INCIN
Nonwastewater Subcategory WETOX
(containing 1% to <10% TOC) CHOXD
BIODG
D001 Ignitable Liquids based n.a. RORGS
on 66261.21(a)(1) - Ignitable INCIN
Wastewater Subcategory WETOX
(containing <1% TOC) CHOXD
BIODG
D001 Compressed Gases based on RCGAS n.a.
66261.21(a)(3) INCIN
FSUBS
ADGAS fb. INCIN ADGAS fb. (CHOXD; or CHRED)
D001 Ignitable Reactives based WTRRX n.a.
on 66261.21 (a)(2) CHOXD
CHRED
STABL
INCIN
D001 Ignitable Oxidizers based CHRED CHRED
on 66261.21(a)(4) INCIN INCIN
D002 Acid Subcategory based on RCORR NEUTR
66261.22(a)(1) with pH less NEUTR INCIN
than or equal to 2 INCIN
D002 Alkaline Subcategory NEUTR NEUTR
based on 66261.22(a)(1) with INCIN INCIN
pH greater than or equal to 12.5
D002 Other Corrosives based on CHOXD CHOXD
66261.22(a)(2) CHRED CHRED
INCIN INCIN
STABL
D003 Water Reactives based on INCIN n.a.
66261.23(a)(2), (3), and (4) WTRRX
CHOXD
CHRED
D003 Reactive Sulfides based CHOXD CHOXD
on 66261.23(a)(5) CHRED CHRED
INCIN BIODG
STABL INCIN
D003 Explosives based on INCIN INCIN
66261.23(a)(6), (7), and (8) CHOXD CHOXD
CHRED CHRED
BIODG
CARBN
D003 Other Reactives based on INCIN INCIN
66261.23(a)(1) CHOXD CHOXD
CHRED CHRED
BIODG
CARBN
K044 Wastewater treatment CHOXD CHOXD
sludges from the manufacturing CHRED CHRED
and processing of explosives INCIN BIODG
CARBN
INCIN
K045 Spent carbon from the CHOXD CHOXD
treatment of wastewaters CHRED CHRED
containing explosives INCIN BIODG
CARBN
INCIN
K047 Pink/red water from TNT CHOXD CHOXD
operations CHRED CHRED
INCIN BIODG
CARBN
INCIN

NOTE: "n.a." stands for "not applicable"; "fb." stands for "followed by".

Notes

Cal. Code Regs. Tit. 22, div. 4.5, ch. 18, app VI

Note: Authority cited: Sections 208, 25150, 25159 and 25179.6, Health and Safety Code. Reference: Sections 25150, 25159, 25159.5 and 25179.6, Health and Safety Code; 40 CFR Part 268 Appendix VI.

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.