Cal. Code Regs. Tit. 22, § 66264.1032 - Standards: Process Vents
(a) The owner or operator of a facility with
process vents associated with distillation, fractionation, thin-film
evaporation, solvent extraction, or air or steam stripping operations managing
hazardous wastes organic concentrations of at least 10 ppmw shall either:
(1) reduce total organic emissions from all
affected process vents at the facility below 1.4 kg/h (3 lb/h) and 2.8 Mg/yr
(3.1 tons/yr); or
(2) reduce, by
use of a control device, total organic emissions from all affected process
vents at the facility by 95 weight percent.
(b) If the owner or operator installs a
closed-vent system and control device to comply with the provisions of
subsection (a) of this section the closed-vent system and control device shall
meet the requirements of Section
66264.1033.
(c) Determinations of vent emissions and
emission reduction or total organic compound concentrations achieved by add-on
control devices shall be based on engineering calculations or performance
tests. If performance tests are used to determine vent emissions, emission
reductions, or total organic compound concentrations achieved by add-on control
devices, the performance tests shall conform with the requirements of Section
66264.1034(c).
(d) When an owner or operator and the
Department do not agree on determinations of vent emissions and/or emission
reductions or total organic compound concentrations achieved by add-on control
devices based on engineering calculations, the procedures in Section
66264.1034(c)
shall be used to resolve the disagreement.