Cal. Code Regs. Tit. 22, § 66264.1055 - Standards: Sampling Connecting Systems
(a) Each sampling connection system shall be
equipped with a closed-purge, closed-loop, or closed-vent system. This system
shall collect the sample purge for return to the process or for routing to the
appropriate treatment system. Gases displaced during filling of the sample
container are not required to be collected or captured.
(b) Each closed-purge, closed-loop, or
closed-vent system as required in subsection (a) of this section shall meet one
of the following requirements:
(1) return the
purged process fluid directly to the process line;
(2) collect and recycle the purged process
fluid; or
(3) be designed and
operated to capture and transport all the purged process fluid to a waste
management unit that complies with the applicable requirements of sections
66264.1084 through
66264.1086 or a control device
that complies with the requirements of section
66264.1060.
(c)
In-situ sampling systems
and sampling systems without purges are exempt from the requirements of
subsections (a) and (b) of this section.
Notes
2. Change without regulatory effect repealing section and adding new section and amending NOTE filed 6-11-99 pursuant to Health and Safety Code section 25159.1 (Register 99, No. 24).
Note: Authority cited: Sections 25150, 25159, 25159.5, 25245 and 58012, Health and Safety Code. Reference: Sections 25150, 25159 and 25159.5, Health and Safety Code; and 40 CFR section 264.1055.
2. Change without regulatory effect repealing section and adding new section and amending Note filed 6-11-99 pursuant to Health and Safety Code section 25159.1 (Register 99, No. 24).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.