Cal. Code Regs. Tit. 22, § 66264.1064 - Recordkeeping Requirements
(a)
(1)
Each owner or operator subject to the provisions of this article shall comply
with the recordkeeping requirements of this section.
(2) An owner or operator of more than one
hazardous waste management unit subject to the provisions of this article may
comply with the recordkeeping requirements for these hazardous waste management
units in one recordkeeping system if the system identifies each record by each
hazardous waste management unit.
(b) Owners and operators shall record the
following information in the facility operating record:
(1) for each piece of equipment to which this
article applies:
(A) equipment identification
number and hazardous waste management unit identification;
(B) approximate locations within the facility
(e.g., identify the hazardous waste management unit on a facility plot
plan);
(C) type of equipment (e.g.,
a pump or pipeline valve);
(D)
percent-by-weight total organics in the hazardous waste stream at the
equipment;
(E) hazardous waste
state at the equipment (e.g., gas/vapor or liquid);
(F) method of compliance with the standard
(e.g., "monthly leak detection and repair" or "equipped with dual mechanical
seals");
(2) for
facilities that comply with the provisions of Section
66264.1033(a)(2),
an implementation schedule as specified in Section
66264.1033(a)(2);
(3) an owner or operator who chooses to use
test data to demonstrate the organic removal efficiency or total organic
compound concentration achieved by the control device, shall record a
performance test plan as specified in Section
66264.1035(b)(3);
and
(4) documentation of compliance
with Section
66264.1060; including the detailed
design documentation or performance test results specified in Section
66264.1034(b)(4).
(c) When each leak is detected as specified
in Sections
66264.1052,
66264.1053,
66264.1057, and
66264.1058, the following
requirements apply:
(1) a weatherproof and
readily visible identification, marked with the equipment identification
number, the date evidence of a potential leak was found in accordance with
Section 66264.1058(a),
and the date the leak was detected, shall be attached to the leaking
equipment;
(2) the identification
on equipment, except on a valve, may be removed after it has been repaired;
and
(3) the identification on a
valve may be removed after it has been monitored for two successive months as
specified in Sections
66264.1057(c) and
no leak has been detected during those two months.
(d) When each leak is detected as specified
in Sections
66264.1052,
66264.1053,
66264.1057, and
66264.1058, the following
information shall be recorded in an inspection log and shall be kept in the
facility operating record:
(1) the instrument
and operator identification numbers and the equipment identification
number;
(2) the date evidence of a
potential leak was found in accordance with Section
66264.1058(a);
(3) the date the leak was detected and the
dates of each attempt to repair the leak;
(4) repair methods applied in each attempt to
repair the leak;
(5) "above 10,000"
if the maximum instrument reading measured by the methods specified in Section
6626.1063(b) after each repair attempt is equal to or greater than 10,000
ppm;
(6) "repair delayed" and the
reason for the delay if a leak is not repaired within 15 calendar days after
discovery of the leak;
(7) source
of documentation supporting the delay of repair of a valve in compliance with
Section 66264.1059(c);
(8) name and the signature of the owner or
operator (or designate) whose decision it was that repair could not be effected
without a hazardous waste management unit shutdown;
(9) the expected date of successful repair of
the leak if a leak is not repaired within 15 calendar days; and
(10) the date of successful repair of the
leak.
(e) Design
documentation and monitoring, operating, and inspection information for each
closed-vent system and control device required to comply with the provisions of
Section 66264.1060 shall be recorded and
kept up-to-date in the facility operating record as specified in Section
66264.1035(c).
Design documentation is specified in Section
66264.1035(c)(1) and
(c)(2), and monitoring, operating, and
inspection information is specified in 66264.1035(c)(3) through
(c)(8).
(f) For a control device
other than a thermal vapor incinerator, catalytic vapor incinerator, flare,
boiler, process heater, condenser, or carbon adsorption system, the Department
will specify the appropriate recordkeeping requirements.
(g) The following information pertaining to
all equipment subject to the requirements in Sections
66264.1052 through
66264.1060 shall be recorded in a
log that is kept in the facility operating record:
(1) a list of identification numbers for
equipment (except welded fittings) subject to the requirements of this
article;
(2)
(A) a list of identification numbers for
equipment that the owner or operator elects to designate for no detectable
emissions, as indicated by an instrument reading of less than 500 ppm above
background, under the provisions of Sections
66264.1052(e),
66264.1053(i),
and 66264.1057(f);
(B) the designation of this equipment as
subject to the requirements of Sections
66264.1052(e),
66264.1053(i), or
66264.1057(f),
and 66264.1057(f)
shall be signed by the owner or operator;
(3) a list of equipment identification
numbers for pressure relief devices required to comply with Section
66264.1054(a).
(4)
(A) the
dates of each compliance test required in Sections
66264.1052(e),
66264.1053(i),
66264.1054, and
66264.1057(f);
(B) the background level measured during each
compliance test;
(C) the maximum
instrument reading measured at the equipment during each compliance test;
and
(5) a list of
identification numbers for equipment in vacuum service.
(6) Identification, either by list or
location (area or group) of equipment that contains or contacts hazardous waste
with an organic concentration of at least 10 percent by weight for less than
300 hours per calendar year.
(h) The following information pertaining to
all valves subject to the requirements of Section
66264.1057(g) and
(h) shall be recorded in a log that is kept
in the facility operating record:
(1) a list
of identification numbers for valves that are designated as unsafe to monitor,
an explanation for each valve stating why the valve is unsafe to monitor, and
the plan for monitoring each valve;
(2) a list of identification numbers for
valves that are designated as difficult to monitor, an explanation for each
valve stating why the valve is difficult to monitor, and the planned schedule
for monitoring each valve.
(i) The following information shall be
recorded in the facility operating record for valves complying with Section
66264.1062:
(1) a schedule of monitoring; and
(2) the percent of valves found leaking
during each monitoring period.
(j) The following information shall be
recorded in a log that is kept in the facility operating record:
(1) criteria required in Section
66264.1052(d)(5)(B)
and Section
66264.1053(e)(2)
and an explanation of the design criteria; and
(2) any changes to these criteria and the
reasons for the changes;
(k) The following information shall be
recorded in a log that is kept in the facility operating record for use in
determining exemptions as provided in the applicability section of this article
and other specific articles:
(1) an analysis
determining the design capacity of the hazardous waste management
unit;
(2) a statement listing the
hazardous waste influent to and effluent from each hazardous waste management
unit subject to the requirements in Sections
66264.1052 through
66264.1060 and an analysis
determining whether these hazardous wastes are heavy liquids; and
(3) an up-to-date analysis and the supporting
information and data used to determine whether or not equipment is subject to
the requirements in Sections
66264.1052 through
66264.1060. The record shall
include supporting documentation as required by Section
66264.1063(d)(3)
when application of the knowledge of the nature of the hazardous waste stream
or the process by which it was produced is used. If the owner or operator takes
any action (e.g., changing the process that produced the waste) that could
result in an increase in the total organic content of the waste contained in or
contacted by equipment determined not to be subject to the requirements in
Sections 66264.1052 through
66264.1060, then a new
determination is required.
(l) Records of the equipment leak information
required by paragraph (d) of this section and the operating information
required by paragraph (e) of this section shall be kept only three
years.
(m) The owner or operator of
a facility with equipment that is subject to this article and to regulations at
40 CFR part 60, part 61, or part 63 may elect to determine compliance with this
article either by documentation pursuant to section
66264.1064, or by documentation of
compliance with the regulations at 40 CFR part 60, part 61, or part 63 pursuant
to the relevant provisions of the regulations at 40 part 60, part 61, or part
63. The documentation of compliance under regulations at 40 CFR part 60, part
61, or part 63 shall be kept with or made readily available with the facility
operating record.
Notes
2. Change without regulatory effect amending subsection (j)(1) filed 12-28-95 pursuant to section 100, title 1, California Code of Regulations (Register 95, No. 52).
3. Change without regulatory effect adding subsection (g)(6) and amending subsection (m) and NOTE filed 6-11-99 pursuant to Health and Safety Code section 25159.1 (Register 99, No. 24).
Note: Authority cited: Sections 25150, 25159, 25159.5, 25245 and 58012, Health and Safety Code. Reference: Sections 25150, 25159 and 25159.5, Health and Safety Code; and 40 CFR, Section 264.1064.
2. Change without regulatory effect amending subsection (j)(1) filed 12-28-95 pursuant to section 100, title 1, California Code of Regulations (Register 95, No. 52).
3. Change without regulatory effect adding subsection (g)(6) and amending subsection (m) and Note filed 6-11-99 pursuant to Health and Safety Code section 25159.1 (Register 99, No. 24).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.