(b) Groundwater Monitoring System.
(1) Except as provided under subsection
(e)(3) of this section, the owner or operator shall establish a groundwater
monitoring system for each regulated unit. The design of the groundwater
monitoring system shall be based upon the information obtained from
hydrogeologic investigations of the facility area, including the identification
of the uppermost aquifer and aquifers hydraulically interconnected and a
determination of groundwater flow rate and direction in each such aquifer. This
groundwater monitoring system shall be fully operational within 180 days of
July 1, 1991. Until such groundwater monitoring system is fully operational,
the owner or operator shall continue to comply with 40 CFR Part
265, Subpart F.
This groundwater monitoring system shall include:
(A) a sufficient number of background
monitoring points (at least one) installed at appropriate locations and depths
to yield groundwater samples from the uppermost aquifer that represent the
quality of groundwater that has not been affected by a release from the
regulated unit;
(B) for a detection
monitoring program under section
66265.98:
1. a sufficient number of monitoring points
(at least three) installed at appropriate locations and depths to yield
groundwater samples from the uppermost aquifer that represent the quality of
groundwater passing the point of compliance and to allow for the detection of a
release from the regulated unit;
2.
a sufficient number of monitoring points installed at additional locations and
depths to yield groundwater samples from the uppermost aquifer as necessary to
provide the best assurance of the earliest possible detection of a release from
the regulated unit; and
3. a
sufficient number of monitoring points and background monitoring points
installed at appropriate locations and depths to yield groundwater samples from
other aquifers, low-yielding saturated zones and from zones of perched water as
necessary to provide the best assurance of the earliest possible detection of a
release from the regulated unit; and
(C) for an evaluation monitoring program
under section
66265.99:
1. a sufficient number of monitoring points
(at least three) installed at appropriate locations and depths to yield
groundwater samples from the uppermost aquifer that represent the quality of
groundwater passing the point of compliance, and at other locations in the
uppermost aquifer as necessary, to provide the data needed to evaluate changes
in water quality due to the release from the regulated unit; and
2. a sufficient number of monitoring points
and background monitoring points installed at appropriate locations and depths
to yield groundwater samples from other aquifers, low-yielding saturated zones
and zones of perched water as necessary to provide the data needed to evaluate
changes in water quality due to the release from the regulated
unit.
(2) The
groundwater monitoring system may include background monitoring points that are
not hydraulically upgradient of the regulated unit if documentation is
maintained in the facility operating record that demonstrates that sampling at
other monitoring points will provide samples that are representative of the
background quality of groundwater or are more representative than those
provided by the upgradient monitoring points.
(3) A copy of each well report, as required
by Water Code section
13751, shall be
submitted to the Department within 60 days of the construction, alteration, or
destruction of the well.
(4) All
monitoring wells shall be cased and constructed in a manner that maintains the
integrity of the monitoring well bore hole and prevents the bore hole from
acting as a conduit for contaminant transport.
(5) The sampling interval of each monitoring
well shall be appropriately screened and fitted with an appropriate filter pack
to enable collection of representative groundwater samples.
(6) For each monitoring well the annular
space (i.e., the space between the bore hole and well casing) above and below
the sampling interval shall be appropriately sealed to prevent entry of
contaminants from the surface, entry of contaminants from the unsaturated zone,
cross contamination of saturated zones and contamination of samples.
(7) All monitoring wells shall be adequately
developed to enable collection of representative groundwater samples.
(8) All wells shall be adequately destroyed
(decommissioned) if the wells no longer provide useful information.
Decommissioning may only proceed after approval by the Department or as
directed by the Department.
(d) Unsaturated Zone Monitoring System.
(1) Except as otherwise provided in
subsection (d)(5) of this section, the owner or operator shall establish an
unsaturated zone monitoring system for each regulated unit.
(2) The unsaturated zone monitoring system
shall include:
(A) a sufficient number of
background monitoring points established at appropriate locations and depths to
yield soil-pore liquid samples or soil-pore liquid measurements that represent
the quality of soil-pore liquid that has not been affected by a release from
the regulated unit;
(B) for a
detection monitoring program under section
66265.98, a sufficient number of
monitoring points established at appropriate locations and depths to yield
soil-pore liquid samples or soil-pore liquid measurements that provide the best
assurance of the earliest possible detection of a release from the regulated
unit; and
(C) for an evaluation
monitoring program under section
66265.99, a sufficient number of
monitoring points established at appropriate locations and depths to yield
soil-pore liquid samples or soil-pore liquid measurements as necessary to
provide the data needed to evaluate changes in water quality due to the release
from the regulated unit.
(3) Background monitoring points shall be
installed at a background plot having soil characteristics similar to those of
the soil underlying the regulated unit.
(4) The owner or operator shall install
liquid recovery types of unsaturated zone monitoring (e.g., the use of
lysimeters) unless the owner or operator submits to the Department, and
maintains in the facility operating record, evidence that such methods of
unsaturated zone monitoring cannot provide useful information regarding a
release from the regulated unit. The owner or operator shall install
complementary or alternative (nonliquid recovery) types of unsaturated zone
monitoring as necessary to adequately monitor a release from the regulated
unit.
(5) The owner or operator may
modify or exclude certain chapter 15, article 6 requirements pertaining to
unsaturated zone monitoring if it is impracticable (e.g., insufficient liquid
volume for analyses) or technically inappropriate to conduct unsaturated zone
monitoring at the regulated unit. The owner or operator shall make an
appropriate demonstration for alternative unsaturated zone monitoring
requirements and obtain written approval from the Department before
incorporating any changes into the water quality sampling and analysis
plan.
(6) The owner or operator of
a land treatment unit shall comply with the unsaturated zone monitoring and
response requirements for that unit in article 13 of this chapter, in addition
to the unsaturated zone monitoring requirements of this
article.
(e) General
Monitoring Requirements.
(1) All monitoring
systems shall be designed and certified by a registered geologist or a
registered civil engineer.
(2) All
monitoring wells and all other borings drilled to satisfy the requirements of
this article shall be logged during drilling under the direct supervision of a
registered geologist. These logs shall be submitted to the Department upon
completion of drilling.
(A) Soil shall be
described in the geologic log according to the Unified Soil Classification
System as presented in Geotechnical Branch Training Manuals Nos. 4, 5 and 6,
published by the United States Bureau of Reclamation, January 1986,
incorporated by reference in section
66260.11 of this
division.
(B) Rock shall be
described in the geologic log in a manner appropriate for the purpose of the
investigation.
(C) Where possible,
the depth and thickness of saturated zones shall be recorded in the geologic
log.
(3) If a facility
contains contiguous regulated units, separate groundwater monitoring systems
are not required for each such unit if the water quality monitoring program for
each unit will enable the earliest possible detection and measurement of a
release from that unit.
(4) The
water quality monitoring program shall include consistent sampling and
analytical procedures that are designed to ensure that monitoring results
provide a reliable indication of water quality at all monitoring points and
background monitoring points. At a minimum the program shall include a detailed
description of the procedures and techniques for:
(A) sample collection (e.g., purging
techniques, sampling equipment and decontamination of sampling
equipment);
(B) sample preservation
and shipment;
(C) analytical
procedures; and
(D) chain of
custody control.
(5) The
water quality monitoring program shall include appropriate sampling and
analytical methods for groundwater, surface water and the unsaturated zone that
accurately measure the concentration of each constituent of concern and the
concentration or value of each monitoring parameter.
(6) For each regulated unit, the owner or
operator shall collect all data necessary for selecting the appropriate
statistical methods pursuant to subsections (e)(7), (e)(8) and (e)(9) of this
section and for establishing the background values pursuant to subsection
(e)(11) of this section. At a minimum, this data shall include analytical data
obtained during quarterly sampling of all background monitoring points for a
period of one year, including the times of expected highest and lowest annual
elevations of the groundwater surface. The Department may approve sampling at
times other than the expected highest and lowest annual elevations, if
appropriate, however quarterly sampling is still required for a period of at
least one year. For a new regulated unit, this data shall be collected before
wastes are discharged at the unit and background soil pore liquid data shall be
collected from beneath the unit before the unit is constructed.
(7) Based on data collected pursuant to
subsection (e)(6) of this section the owner or operator shall select one of the
statistical methods specified in subsection (e)(8) of this section for each
constituent of concern and for each monitoring parameter. These methods shall
be specified in the water quality sampling and analysis plan and shall be used
in evaluating water quality monitoring data. The specifications for each
statistical method shall include a detailed description of the criteria to be
used for determining statistically significant evidence of any release from the
regulated unit and for determining compliance with the water quality protection
standard. Each statistical test specified for a particular constituent of
concern or monitoring parameter shall be conducted separately for that
constituent of concern or monitoring parameter at each monitoring point. The
owner or operator shall maintain sufficient documentation in the facility
operating record to demonstrate that use of the selected statistical methods
will be protective of human health and the environment and will comply with the
performance standards outlined in subsection (e)(9) of this section.
(8) The owner or operator shall specify one
of the following statistical methods in the water quality sampling and analysis
plan:
(A) a parametric analysis of variance
(ANOVA) followed in all instances by a multiple comparisons procedure to
identify statistically significant evidence of a release from the regulated
unit. The method shall include estimation and testing of the contrasts between
each monitoring point's mean and the background mean value for each constituent
of concern or monitoring parameter;
(B) an analysis of variance (ANOVA) based on
ranks followed in all instances by a multiple comparisons procedure to identify
statistically significant evidence of a release from the regulated unit. The
method shall include estimation and testing of the contrasts between each
monitoring point's median and the background median values for each constituent
of concern or monitoring parameter;
(C) a tolerance or prediction interval
procedure in which an interval for each constituent of concern or monitoring
parameter is established from the distribution of the background data, and the
value for each constituent of concern or monitoring parameter at each
monitoring point is compared to the upper tolerance or prediction
limit;
(D) a control chart approach
that gives control limits for each constituent of concern or monitoring
parameter; or
(E) another
statistical test method if sufficient documentation to support selection of the
method is submitted to the Department and is maintained in the facility
operating record. If the statistical test method includes a procedure to verify
that there is statistically significant evidence of a release from the
regulated unit, this procedure shall consist of either a single composite
retest (i.e., a statistical analysis of the original data combined with
newly-acquired data from the monitoring point at which evidence of a release
has been indicated) or shall consist of at least two discrete retests (i.e.,
statistical analyses which analyze only newly-acquired data from the monitoring
point at which evidence of a release has been indicated). The verification
procedure shall comply with the following requirements in addition to the
statistical performance standards under subsection (e)(9) of this section.
1. If the verification procedure consists of
discrete retests, rejection of the null hypothesis for any one of the retests
shall be considered confirmation of significant evidence of a
release.
2. The number of
additional samples collected and analyzed for use in the verification procedure
shall be appropriate for the form of statistical test specified in the water
quality sampling and analysis plan for that constituent of concern or
monitoring parameter pursuant to subsection (e)(7) of this section. This number
shall be greater than or equal to the number of samples specified in the water
quality sampling and analysis plan for that constituent of concern or
monitoring parameter pursuant to subsection (e)(12)(A) of this
section.
3. If resampling at the
interval identified for use in the initial statistical test pursuant to
subsection (e)(12)(B) of this section would cause the entire resampling effort
to take longer than 30 days, the sampling interval for use in the verification
procedures shall be reduced to ensure that all samples are collected and
submitted for laboratory analysis within 30 calendar days from the time that
the owner or operator determines statistically significant evidence of a
release pursuant to subsection
66265.98(g) or
(i). Resampling may occur within a different
time frame provided the owner or operator receives written approval from the
Department.
4. For a verification
procedure consisting of a composite retest, the statistical verification
procedure shall be based on all data obtained from the initial sampling event
combined with all data obtained during the resampling event. For a verification
procedure consisting of discrete retests, each shall analyze data obtained
during its respective resampling event and no data shall be shared between
retests.
5. For a verification
procedure consisting of a composite retest, the statistical test method used in
the verification procedure shall be the same as the method used in the initial
statistical comparison, except that the statistical test used in the
verification procedure shall be conducted at a Type 1 error level of no less
than 0.05 for both the experimentwise analysis (if any) and the individual
monitoring point comparisons; therefore, if a control chart approach is used to
evaluate water quality monitoring data, the upper limit on an X-Bar or R-Chart
must be set at no more than 1.645 standard deviations of the statistic plotted
for a one-sided statistical comparison or at no more than 1.96 standard
deviations of the statistic plotted for a two-sided statistical
comparison.
6. For a verification
procedure consisting of discrete retests, the statistical method used shall be
the same as the method used in the initial statistical comparison.
Notwithstanding any provision of subsection (e)(9) of this section, the
critical value for the tests shall be chosen so that the Type I error rate for
all individual monitoring point comparisons is the same, whether for an initial
test or for a retest, and is equal-to-or-greater than either
1-0.
951/(mws))0.5 x
(1/r)0.5
or
1-(.99)1/6
whichever is larger, where: m = the number of monitoring
parameters; w = the number of monitoring points at the waste management units;
s = the number of times that suites of monitoring data from the waste
management unit are subjected to initial statistical analysis within a period
of six months (i.e., s > 1); and r = the number of discrete retests that are
to be conducted at a monitoring point whose initial statistical analysis for a
given constituent of concern or monitoring paramenter has indicated the
presence of a release (i.e., r > 2).
7. The owner or operator shall report to the
Department by certified mail the results of both the initial statistical test
and the results of the verification procedure as well as all concentration data
collected for use in these tests within seven days of the last laboratory
analysis of the samples collected for the verification procedure.
8. The verification procedure shall only be
performed for the constituent(s) which has shown statistically significant
evidence of a release, and shall only be performed for that (those) monitoring
point at which a release has been indicated.
(9) Each statistical method chosen under
subsection (e)(7) of this section shall comply with the following performance
standards for each six-month period.
(A) The
statistical method used to evaluate water quality monitoring data shall be
appropriate for the distribution of the constituent of concern or monitoring
parameter to which it is applied and shall be the least likely of the
appropriate methods to fail to identify a release from the regulated unit. If
the distribution of a constituent of concern or monitoring parameter is
inappropriate for a normal theory test, then the data shall be either
transformed so that the distribution of the transformed data is appropriate for
a normal theory test or a distribution-free theory test shall be used. If the
distributions for the constituents of concern or monitoring parameters differ,
more than one statistical method may be needed.
(B) If an individual monitoring point
comparison procedure is used to compare an individual monitoring point
constituent concentration or monitoring parameter value with a background
parameter value or with a concentration limit in the water quality protection
standard or with a background monitoring parameter value, the test shall be
done at a Type I error level no less than 0.01. If a multiple comparisons
procedure is used, the Type I experimentwise error rate shall be no less than
0.05; however, the Type I error of no less than 0.01 for each individual
monitoring point comparison shall be maintained. This performance standard does
not apply to tolerance intervals, prediction intervals or control
charts.
(C) If a control chart
approach is used to evaluate water quality, monitoring data, the specific type
of control chart and its associated statistical parameter values (e.g., the
upper control limit), shall be protective of human health and the environment.
Any control charting procedure must have a false-positive rate of no less than
1 percent for each monitoring point charted (e.g., upper control limits on
X-bar or R-charts used only once every six months must be set at no more than
2.327 standard deviations of the statistic plotted for a one-sided statistical
comparison or at no more than 2.576 standard deviations of the statistic
plotted for a two-sided statistical comparison).
(D) If a tolerance interval or a prediction
interval is used to evaluate water quality monitoring data, the levels of
confidence and, for tolerance intervals, the percentage of the population that
the interval must contain shall be protective of human health and the
environment. These statistical parameters shall be determined after considering
the number of samples in the background data base, the data distribution, and
the range of the concentrations or values for each constituent of concern or
monitoring parameter. The coverage of any tolerance interval used must be no
more than 95 percent and the confidence coefficient must be no more than 95
percent for a six-month period. Prediction intervals shall be constructed with
an experimentwise error rate of no less than 5 percent and an individual
monitoring point error rate of no less than 1 percent.
(E) The statistical method shall account for
data below the practical quantification quantitation limit with one or more
statistical procedures that are protective of human health and the environment.
Any practical quantitation limit that is used in the statistical method shall
be the lowest concentration (or value) that can be reliably achieved within
limits of precision and accuracy specified in the water quality sampling and
analysis plan for routine laboratory operating conditions that are available to
the facility.
(F) If necessary, the
statistical methods shall include procedures to control or correct for seasonal
and spatial variability as well as temporal correlation in the data.
(G) Any quality control procedure that is
approved by the Department for application to water quality data from
downgradient monitoring points for a monitored medium shall also be applied to
all newly-acquired background data from that medium. Any newly-acquired
background monitoring datum that is rejected by an approved quality control
procedure shall be maintained in the facility record but shall be excluded from
use in statistical comparisons with downgradient water quality
data.
(10) Based on the
data collected pursuant to subsection (e)(6) of this section and the
statistical methods specified pursuant to subsection (e)(7) of this section,
the owner or operator shall select and justify the use of a procedure for
determining a background value for each constituent of concern and for each
monitoring parameter specified in the water quality sampling and analysis plan.
One of the following procedures shall be selected for groundwater, surface
water and the unsaturated zone:
(A) a
procedure for determining the background value for each constituent or
parameter that does not display appreciable natural variation; or
(B) a procedure for establishing and updating
the background value for a constituent or parameter to reflect changes in the
background water quality if the use of contemporaneous or pooled data provides
the greatest power to the statistical method for that constituent or
parameter.
(11) Using the
procedures for determining background values proposed pursuant to subsection
(e)(10) of this section, the owner or operator shall specify in the water
quality sampling and analysis plan one of the following for each constituent of
concern and for each monitoring parameter:
(A) the background value established by the
owner or operator using the procedure selected pursuant to subsection
(e)(10)(A) of this section; or
(B)
a detailed description of the procedure, selected pursuant to subsection
(e)(10)(B) of this section, to be used by the owner or operator for
establishing and updating the background value.
(12) For each constituent of concern and
monitoring parameter listed in the water quality sampling and analysis plan,
the owner or operator shall specify in the water quality sampling and analysis
plan the sampling methods to be used to establish background values and the
sampling methods to be used for monitoring pursuant to this article.
(A) The number and kinds of samples collected
shall be appropriate for the form of statistical test employed, following
generally accepted statistical principles. The sample size shall be as large as
necessary to ensure with reasonable confidence that:
1. for a detection monitoring program, a
release from the regulated unit will be detected; and
2. for an evaluation monitoring program,
changes in water quality due to a release from the regulated unit will be
recognized.
(B) The
sampling method (including sampling frequency and the interval of time between
successive samples) shall be appropriate for the medium from which samples are
taken (e.g., groundwater, surface water and soil-pore liquid). The sampling
method shall include either:
1. a sequence of
at least four samples from each monitoring point, taken at an interval that
assures, to the greatest extent technically feasible, that an independent
sample is obtained. For groundwater, this interval shall be based upon the rate
of groundwater movement in the aquifer and upon the fate and transport
characteristics of the potential contaminants or pollutants. The rate of
groundwater movement shall be calculated by reference to the aquifer's
effective porosity, hydraulic conductivity and hydraulic gradient; or
2. an alternate sampling method if sufficient
documentation is submitted to the Department and is maintained in the facility
operating record to support selection of the
method.
(13)
The groundwater portion of the monitoring program shall include an accurate
determination of the groundwater surface elevation and field parameters
(temperature, electrical conductivity, turbidity and pH) at each well each time
groundwater is sampled. Field parameter determinations may be modified or
waived, after receiving written approval by the Department, if the owner or
operator can demonstrate that representative samples are obtained. Any
modifications to field parameter determinations shall be specified in the water
quality sampling and analysis plan.
(14) The owner or operator shall graph all
analytical data from each monitoring point and background monitoring point and
shall submit these graphs to the Department at least annually, except graphs
are not required for constituents for which no new data have been collected
since the previous graph submittal. Each graph shall represent data for one
constituent of concern or monitoring parameter and shall be at a scale
appropriate to show trends or variations in water quality. Unless the owner or
operator receives written approval from the Department to use an alternate
procedure, each graph shall include data from related monitoring and background
points as long as the depicted data effectively illustrates trends or
variations in the data.
(15) In
addition to the water quality sampling conducted pursuant to the requirements
of this article, the owner or operator shall measure the water level in each
well and determine groundwater flow rate and direction in the uppermost aquifer
and in any zones of perched water and in any additional aquifers monitored
pursuant to subsection (b)(1) of this section at least quarterly, including the
times of expected highest and lowest annual elevations of the water levels in
the wells. The Department may approve collection of water level measurements at
times other than the expected highest and lowest water level elevations, if
appropriate, however quarterly measurements are still required. The owner or
operator shall use this data to determine, at least annually, whether the
requirements of section
66265.97(b)(1)
are satisfied. If the evaluation shows that the requirements of section
66265.97(b)(1)
are not satisfied the owner or operator shall, as soon as technically feasible,
modify the number, location or depth of the groundwater monitoring wells as
necessary to bring the groundwater monitoring system into compliance with the
requirements of this article.
(16)
Except as provided below, for all background monitoring points in groundwater,
the owner or operator must, within 12 months of July 1, 1991, establish
background concentrations or values for all constituents listed in Table 1 by
sampling quarterly for one year. Results of this sampling shall be submitted to
the Department within 15 days after completing each quarterly analysis. If an
owner or operator has previously established background for these parameters
pursuant to 40 C.F.R. Part
265 by quarterly sampling for at least one year, the
owner or operator shall maintain a record of that sampling and analysis in the
facility operating record and shall not repeat the sampling and analysis.
Table 1
Background Water Quality Parameters
|
Arsenic |
Barium |
|
|
Cadmium |
Chloride |
|
|
Chromium |
Coliform Bacteria |
|
|
Endrin |
Fluoride |
|
|
Gross Alpha |
Gross Beta |
|
|
Iron |
Lead |
|
|
Lindane |
Manganese |
|
|
Mercury |
Methoxychlor |
|
|
Nitrate (as N) |
pH |
|
|
Phenols |
Radium |
|
|
Selenium |
Silver |
|
|
Sodium |
Specific Conductance |
|
|
Sulfate |
Toxaphene |
|
|
2,4-D |
2,4,5.TP Silver |
|
|
Total Organic Carbon |
Total Organic
Halogen |
|
|
Turbidity |
|
(17) Water quality monitoring data collected
in accordance with this article, including actual concentrations or values of
all constituents and parameters, all background water quality data, all
statistical evaluations, all water level elevation data and all data used to
derive the groundwater flow rate and direction shall be maintained in the
facility operating record throughout the active life of the facility and
throughout the postclosure care period. The owner or operator shall submit this
data to the Department at least annually. This information shall be submitted
no later than March 1 following each calendar year. The Department shall
require more frequent reporting where necessary to protect human health or the
environment.