Conn. Agencies Regs. § 19-13-B45 - Minimum requirements for drainage and toilet systems
(a) Plumbing and drainage systems shall be so
constructed as to avoid contamination of safe drinking water supplies in houses
or buildings. There shall be no cross connections between such safe water
supplies and unsafe water supplies nor shall such safe supplies be piped to
refrigeration, air conditioning or other mechanical equipment provided with
direct connections to drains or constructed in such a manner as to permit
contaminated water to be siphoned or drawn into the water supply pipes. Storage
of drinking water in buildings shall be only in covered tanks so constructed as
to avoid any possible contamination of the water in the tanks. Sewer or waste
lines located above storage tanks and direct overflows and drains to sewer
systems are expressly prohibited.
(b) Buildings in which water closets and
other plumbing fixtures exist shall be provided with a supply of water adequate
in volume and pressure for flushing purposes.
(c) The pipe system shall be of sufficient
size to supply water for adequate flushing of toilet fixtures without unduly
reducing the pressure at other fixtures.
(d) Devices for heating water and storing it
in "boilers" or hot water tanks shall be so designed and installed as to
prevent all dangers from explosion.
(e) Each tenement, lodging or boarding house
located on premises abutting any street or alley where running water is
available and through which there is a sewer with which connection may be had
shall be provided with water closets connected with such sewer. All other
buildings used or intended to be used for human habitation or occupancy on
premises abutting a street in which there is a public sewer shall be connected
with such sewer whenever required by the local authorities having
jurisdiction.
(f) Tenement houses
erected prior to September 1, 1930, and provided with house drainage systems
shall be furnished with at least one water closet for each two apartments of
three rooms or less each, and one such closet for each apartment of four or
more rooms. Tenement houses erected after August 31, 1930, and prior to July 1,
1941, shall have a water closet in each apartment of three or more rooms and at
least one water closet for each two apartments of less than three rooms each.
In each tenement house erected or subdivided after June 30, 1941, there shall
be a water closet in each apartment of two or more rooms.
(g) Plumbing fixtures shall be made of smooth
nonabsorbent material, shall be free from concealed fouling surfaces and shall
be set free of enclosures.
(h) The
entire house drainage system shall be so designed, constructed and maintained
as to conduct the waste water or sewage quickly from the fixture to the place
of disposal with velocities which will guard against fouling and the deposit of
solids and will prevent clogging.
(i) The drainage pipes shall be so designed
and constructed as to be proof for a reasonable life of the building against
leakage of water or drain air due to defective materials, imperfect
connections, corrosion, settlements or vibrations of the ground or building,
temperature changes, freezing or other causes.
(j) The drainage system shall be provided
with an adequate number of cleanouts so arranged that in case of stoppage the
pipes may be readily accessible.
(k) Each fixture or combination fixture shall
be provided with a separate, accessible, self-scouring, reliable water-seal
trap placed as near to the fixture as possible.
(l) The house-drainage system shall be so
designed that there will be an adequate circulation of air in all pipes and no
danger of siphonage, aspiration or forcing of trap seals under conditions of
ordinary use.
(m) The soil stack
shall extend full size upward through the roof and have a free opening, the
roof terminal being so located that there will be no danger of air passing from
it to any window and no danger of clogging of the pipe by frost or by articles
being thrown into it or of roof water draining into it.
(n) The plumbing system shall be subjected to
a water or air-pressure test and to a final air-pressure, smoke or peppermint
test in such a manner as to disclose all leaks and imperfections in the
work.
(o) No substances which will
clog the pipes, produce explosive mixtures or destroy the pipes or their joints
shall be allowed to enter the house drainage system.
(p) Refrigerators, ice boxes or receptacles
for storing food shall not be connected directly with the drainage
system.
(q) No water closet shall
be located in a room or compartment which is not properly lighted and
ventilated to the outer air.
(r) If
water closets or other plumbing fixtures exist in buildings where there is no
public sewer accessible, suitable provision shall be made for disposing of the
sewage without nuisance. The location and construction of private sewage
disposal systems shall conform to the requirements of sections 19-13-B20a to
19-13-B20r, inclusive.
(s) Where a
house-drainage system may be subjected to back flow of sewage, suitable
provision shall be made to prevent its overflow in the building.
(t) No plumbing fixture nor waste outlet
shall be installed which will provide a cross connection between a distributing
system of water for drinking and domestic purposes and a drainage system, soil
or waste pipe and permit or make possible the back flow or siphonage of sewage
or waste into the water supply.
Note: Attention is directed to the danger from underrim water inlet fixtures and flushometer valves without adequate vacuum breakers.
(u) All drinking
fountain installations or replacements after January 12, 1954, shall be
constructed with a slanting jet issuing from a nozzle of non-oxidizing
impervious material with a non-oxidizing guard to prevent the mouths and noses
of persons using the fountain from coming in contact with the nozzle. The jet
shall be located so as not to touch the guard and shall be discharged at such
an angle that the water can neither fall back nor be forced back on to the
point of discharge. The fountain jet and all openings in the water supply
piping shall issue above the level of the fountain bowl. The drainage from the
bowl shall be adequate and so constructed as to prevent fouling of the bowl.
The drain from the fountain shall not have a direct physical connection to a
waste pipe unless the drain is trapped. The waste opening and pipe from the
fountain shall be of sufficient size to carry off the water promptly. The
opening shall be provided with a strainer. All drinking fountains installed
after January 12, 1954, shall be provided with their own receiving bowls and
shall not be installed over sinks used for hand washing or other
purposes.
(v) Plumbing systems
shall be maintained in a sanitary condition.