Fla. Admin. Code Ann. R. 64E-5.440 - Records
(1) Each licensee or
registrant shall maintain the following records for 3 years after the event at
the location specified in Rule
64E-5.432, F.A.C., for
inspection by the Department:
(a) Survey
instrument, dosimeter, and alarm ratemeter calibrations specified in Rule
64E-5.426 and subsections
64E-5.437(5)
-(6), F.A.C.;
(b) Leak test results
specified in Rule 64E-5.427, F.A.C., which shall
contain the manufacturer's name, model, and serial number of each sealed source
or device tested, including the device the source was stored in, the identity
of each radionuclide, the estimated activity of each sealed source, the
measured activity of each test sample expressed in microcuries (becquerels),
the date of the test, and the signature or initials of the RSO or the RSO's
designee;
(c) Quarterly inventories
specified in Rule 64E-5.428, F.A.C., which shall
include the name of the person conducting the inventory, the radionuclide,
number of curies (becquerels) or mass in each device, location of each sealed
source, device, and machine, the manufacturer, model, and serial number of each
sealed source, device, and machine, the date of the inventory, and the
signature or initials of the RSO or the RSO's designee;
(d) Source movement logs and daily survey
reports specified in Rule
64E-5.429, F.A.C.;
(e) Quarterly equipment inspection and
maintenance specified in subsection
64E-5.430(2),
F.A.C., including the date of the inspection, the name of inspector, the
equipment involved, any problems found, and what repair or maintenance was
done;
(f) Operation tests on
permanent radiographic installation entrance controls and audible and visual
alarms specified in Rule
64E-5.431, F.A.C.;
(g) Records of internal audits specified in
subsection 64E-5.434(8),
F.A.C., including lists of audit items checked and any violations
observed;
(h) Records showing
receipts and transfers of sealed sources and devices using DU for shielding,
including the date, the name of the individual making the record, radionuclide,
number of curies (becquerels) or mass, manufacturer, model, and serial number
of each sealed source and device, as appropriate;
(i) Records of annual ALARA audits specified
in paragraph 64E-5.432(4)(c),
F.A.C.
(2) Each licensee
or registrant shall maintain the following records until the Department
terminates the license or registration requiring the record:
(a) Individual dosimeter logs specified in
Rule 64E-5.429, F.A.C.;
(b) Initial and refresher radiation safety
training specified in Rule
64E-5.434, F.A.C., including
lists of the topics discussed, dates the training was conducted, names of the
instructors and attendees, and written and practical examinations;
(c) Verification of previous radiography
experience;
(d) Radiographer
certification documents specified in paragraph
64E-5.434(2)(d),
F.A.C., and verification of certification status;
(e) Records of personnel exposure
investigations specified in paragraph
64E-5.432(4)(b),
F.A.C., including the names of the individuals involved, the exposures
received, the dates the exposures were received, a description of the cause of
the exposures, the corrective actions taken, and the signature of the
RSO;
(f) Records of estimates of
exposures as a result of off-scale dosimeters or lost or damaged personnel
monitoring badges, including records of surveys used to determine an
individual's exposure and reports submitted to the department as specified in
subsection 64E-5.437(3),
F.A.C.;
(g) Personnel monitoring
badge records from the accredited NVLAP processor as specified in subsection
64E-5.437(2),
F.A.C.; and,
(h) Operating and
emergency procedures. Licensees shall retain superseded material for 3 years
after making changes to operating or emergency procedures.
(3) Each licensee or registrant conducting
industrial radiography at a temporary job site shall have the following records
available at that site for inspection by the department:
(a) Appropriate license or
registration;
(b) Certification by
a certifying entity;
(c) Operating
and emergency procedures;
(d) Rules
contained in Chapter 64E-5, Parts I-IV, IX, and XV, F.A.C.;
(e) Calibration records for the survey
instruments, pocket dosimeters, and alarm ratemeters used at the site or
calibration tags or labels that are affixed to the devices;
(f) Records of the latest leak test results
for the specific devices in use at the site or leak test tags or labels that
are affixed to the devices; and,
(g) Source movement logs and daily survey
reports for the period of operation at the site.