Fla. Admin. Code Ann. R. 64E-5.1413 - Power Failures

(1) If electrical power at a panoramic irradiator is lost for longer than 10 seconds, the sources must return automatically to the shielded position.
(2) The lock on the door of the radiation room of a panoramic irradiator must not be deactivated by a power failure.
(3) During a power failure, the area around the pool of an irradiator shall not be entered without using an operable and calibrated radiation survey meter.