Ill. Admin. Code tit. 35, § 615.204 - Groundwater Monitoring System
a)
Except as provided otherwise in subsection (b), the groundwater monitoring
system must consist of a sufficient number of wells, installed at appropriate
locations and depths to yield groundwater samples, that:
1) Represent the quality of background water
that has not been affected by contamination from the facility or unit;
and
2) Represent the quality of
groundwater at the compliance point or points.
b) If a potable water well or other water
well can be used as a monitoring well under this subsection, no additional
monitoring wells are required under this Section. A potable water well or other
water well may be used as a monitoring well if:
1) For a potable water well other than a
community water supply well, a construction report has been filed with the
Illinois Department of Public Health for such well, or such well has been
located and constructed (or reconstructed) to meet the Illinois Water Well
Construction Code [415 ILCS 30 ] and 35 Ill. Adm. Code 920;
2) For a potable water supply well that was
constructed before August 20, 1965, the enactment of the Illinois Water Well
Construction Code [415 ILCS 30 ], and meets all of the following criteria:
A) Construction must be done in a manner that
will enable the collection of groundwater samples that represent in situ
groundwater conditions;
B) Casings
and screens must be made from durable material resistant to expected chemical
or physical degradation that does not interfere with the quality of groundwater
samples being collected; and
C) The
annular space opposite the screened section of the well (i.e., the space
between the bore hole and well screen) must be filled with gravel or sand if
necessary to collect groundwater samples. The annular space above and below the
well screen must be sealed to prevent migration of water from adjacent
formations and the surface to the sampled depth.
3) For a water well other than a potable
water well (e.g., a livestock watering well or an irrigation well), the owner
or operator of the unit seeking to use the well as a monitoring well certifies
to the Agency that a construction report has been filed with the Illinois
Department of Public Health or the Illinois Department of Mines and Minerals
for such well, or that such well has been located and constructed (or
reconstructed) to meet the Illinois Water Well Construction Code [415 ILCS 30 ]
and 35 Ill. Adm. Code 920; and
4)
The unit contains solely non-special waste if the unit is a surface
impoundment.
c) When a
facility contains more than one unit, separate groundwater monitoring systems
are not required for each unit if provisions for sampling the groundwater will
enable detection and measurement of contaminants that have entered the
groundwater from all units.
d) All
monitoring wells must meet the following requirements:
1) Construction must be done in a manner that
will enable the collection of groundwater samples;
2) Casings and screens must be made from
durable material that is resistant to expected chemical or physical degradation
and that does not interfere with the quality of groundwater samples being
collected; and
3) The annular space
opposite the screened section of the well (i.e., the space between the bore
hole and well screen) must be filled with gravel or sand if necessary to
collect groundwater samples. The annular space above and below the well screen
must be sealed to prevent migration of water from overlying adjacent formations
and the surface to the sampled depth.