Ill. Admin. Code tit. 68, § 1410.200 - Standards of Practice
a) This
Subpart defines the practice of home inspection in the State of Illinois by:
1) Defining certain terms relating to home
inspections; and
2) Providing home
inspection and home inspection report guidelines and requirements.
b) The following are terms
commonly used in the writing of home inspection reports.
1) Alarm Systems: Warning devices, installed
or free-standing, including but not limited to carbon monoxide detectors, flue
gas and other spillage detectors, security equipment, ejector pumps and smoke
alarms.
2) Automatic Safety
Controls: Devices designed and installed to protect systems and components from
unsafe conditions.
3) Client: A
person or entity who engages or seeks to engage the services of a home
inspector for an inspection assignment or home inspection report of a
residential real property.
4)
Component: A part of a system.
5)
Decorative: Ornamental; not required for the operation of the essential systems
and components of a home.
6)
Describe: To report a system or component by its type or other observed,
significant characteristics to distinguish it from other systems or
components.
7) Dismantle: To take
apart or remove any component, device or piece of equipment that would not be
taken apart or removed by a homeowner in the course of normal and routine
homeowner maintenance.
8) Further
Evaluation: Examination and analysis by a qualified professional, tradesperson
or service technician beyond that provided by the home inspection.
9) Home Inspection: As defined in Section
1-10 of the Act.
10) Household
Appliances: Include, but are not limited to, range, stove, oven, refrigerator,
window air conditioner, washer, dryer, trash compactor and garbage disposal,
and other appliances that may be part of a real estate transaction, whether
installed or free-standing.
11)
Inspect: To visually examine readily accessible systems and components of a
building in accordance with this Subpart, using normal operating controls and
opening readily accessible panels.
12) Installed: Attached in such a manner that
removal requires tools.
13) Normal
Operating Controls: Devices such as, but not limited to, thermostats, switches
or faucets intended to be operated by the homeowner.
14) Readily Accessible: Available for visual
inspection without requiring moving of personal property, dismantling,
destructive measures, or any action that will likely involve risk to persons or
property.
15) Readily Operable
Access Panel: A panel provided for homeowner inspection and maintenance that is
within normal reach, can be removed by one person, and is not sealed in
place.
16) Recreational Facilities:
Spas, saunas, steam baths, swimming pools, and exercise, entertainment,
athletic, playground, or other similar equipment and associated
accessories.
17) Report: To
communicate in writing in a home inspection report as defined by the Act and
this Part.
18) Representative
Number: One component per room for multiple similar interior components, such
as windows, doors, and electric outlets, and one component on each side of the
building for multiple similar exterior components.
19) Roof Drainage Systems: Components used to
carry water off a roof and away from a building.
20) Significantly Deficient: Unsafe or not
functioning.
21) Shut Down: A state
in which a system or component cannot be operated by normal controls.
22) Solid Fuel Burning Appliances: A hearth
and fire chamber or similar place in which a fire may be built, and that is
built in conjunction with a chimney; or a listed assembly of a fire chamber,
its chimney, and related factory-made parts designed for unit assembly without
requiring field construction.
23)
Structural Component: A component that supports non-variable forces or weights
(dead loads), and variable forces or weights (live loads).
24) System: A combination of interacting or
interdependent components, assembled to carry out one or more
functions.
25) Technically
Exhaustive Inspection: An investigation that involves dismantling or the
extensive use of advanced techniques, measurements, instruments, testing,
calculations, or other means.
26)
Under-floor Crawl Space: The area within the confines of the foundation, and
between the ground and the underside of the floor.
27) Unsafe: A condition in a system or
component that poses a significant risk of personal injury or property damage
during normal, day-to-day use. The risk may be due to damage, deterioration,
improper installation, or a change in accepted residential construction
standards.
28) Wiring Methods:
Includes identification of electrical conductors or wires such as, but not
limited to, non-metallic sheathed cable (Romex), armored cable (BX), or knob
and tube.
c) The purpose
of this Subpart is to establish a minimum and uniform standard for licensed
home inspectors to provide the client with information regarding the condition
of the systems and components of the home as inspected at the time of the home
inspection. The home inspectors shall observe readily visible and accessible
installed systems and components listed as part of a home inspection, unless
the system or component is limited and/or excluded under the executed written
contract (i.e., pre-inspection agreement) with the client.
d) Home inspectors or home inspector entities
shall enter into an executed written contract with the client or duly
authorized representative prior to the home inspection that includes at a
minimum:
1) The purpose of the
inspection;
2) The date of the
inspection;
3) The name, address,
and license numbers of the home inspectors and home inspector entity;
4) The fee for services to be
performed;
5) A statement that the
inspection will be performed, at a minimum, in accordance with the Standards of
Practice in this Part;
6) A list of
the systems and components to be inspected;
7) The signature of the client or the
client's duly authorized representative, and the signature of the home
inspector, or the duly authorized representative of a home inspector entity;
and
8) Limitations or exclusions of
the home inspection services, and the systems or components being inspected.
These may include, but are not limited to, the following:
A) That the home inspector is not required to
determine the condition of any component or system that is not readily
accessible, the service life expectancy of any component or system, or the
cause for the need of replacement of any system or component.
B) That the home inspector is not required to
operate any system that is shut down or that does not turn on with the use of
normal operating controls.
C) That
the home inspector is not required to enter or access any area that may be
unsafe or not readily accessible, perform any engineering or environmental
services, report on future conditions, or offer warranties, guarantees, or
insurance policies of any kind for the property or property systems being
inspected.
e)
Home inspectors or home inspector entities shall submit a written home
inspection report to the client or duly authorized representative within 2
business days after the completed inspection that satisfies, at a minimum, the
following requirements:
1) The home inspection
report may be in electronic format and shall include a written or electronic
signature of the home inspector or the duly authorized representative of a home
inspector entity who conducted the home inspection;
2) The home inspection report shall include
the names and license numbers of all home inspectors who participated in the
home inspection;
3) The on-site
inspection beginning time and the weather conditions at the time of the
inspection;
4) A description of the
condition of the systems and components that were inspected, which may include
photos of the systems and components; and
5) Description of those systems and
components inspected that, in the opinion of the inspector, are significantly
deficient including:
A) A reason why the
system or component is significantly deficient;
B) Whether the reported deficiency should be
corrected or monitored;
C)
Disclosure of any systems or components designated for inspection that were
present at the time of the home inspection but were not inspected, and a reason
as to why they were not inspected, such as any obstructions or conditions that
prevented the inspection.
6) The written home inspection report does
not have to include the names of anyone performing ministerial duties related
to the home inspection that does not alter the content of the report.
f) These Standards of Practice are
not intended to limit home inspectors from:
1)
Including other inspection services, systems, or components in addition to
those defined in these Standards of Practice;
2) Specifying repairs that the licensed home
inspector is qualified and willing to perform; and
3) Excluding systems and components from the
inspection if the exclusion is specified in the executed written contract with
the client.
g) When,
pursuant to the executed written contract with a client, the structural system
and foundation is inspected, the home inspector shall:
1) Inspect the structural components,
including the foundation and framing;
2) Describe the foundation and its
construction type, as well as report the methods used to inspect the
under-floor crawl space or basement area, attic, floor, wall, ceiling, framing,
and roof;
3) Report visible signs
of water and moisture penetration into the building or signs of condensation on
building components; and
4) Report
any infestation that significantly impacts the structure or integrity of the
home.
h) When, pursuant
to the executed written contract with a client, the exterior is inspected, the
home inspector shall:
1) Inspect the exterior
wall covering; exposed foundation; flashing and trim; all exterior doors and
windows; siding; attached decks, balconies, stoops, steps, porches; landings,
and their associated railings; the eaves, soffits, and fascia or other exposed
trim if readily accessible from the ground level; the vegetation, grading,
surface drainage, and retaining walls on the property; and if any of these are
likely to adversely affect the building, walkways, patios, and driveways
leading to dwelling entrances; and
2) Describe the exterior wall
covering.
i) When,
pursuant to the executed written contract with a client, the roof system is
inspected, the home inspector shall:
1)
Inspect the roof covering, roof drainage systems, flashings, skylights,
chimneys, and roof penetrations; and
2) Describe the roof covering and report the
methods used to inspect the roof.
j) When, pursuant to the executed written
contract with a client, the plumbing system is observed, the home inspector
shall:
1) Inspect and describe in detail:
A) the interior water supply and distribution
systems (including fixtures, faucets, piping, drains, waste, and vent
systems);
B) water heating
equipment;
C) fuel storage and
distribution systems; and
D)
drainage sumps, sump pump and related piping; and
2) Report the location of main water and main
shut-off valves, the water service entry, water distribution piping materials,
the type of water heating equipment, the capacity of that equipment, and
leaks.
k) When, pursuant
to the executed written contract with a client, the electrical system is
inspected, the home inspector shall:
1)
Inspect the service drop; service entrance conductors, cables, and raceways;
service equipment and main disconnects; service grounding; interior components
of service panels and subpanels; conductors; overcurrent protection devices; a
representative number of installed lighting fixtures, switches, and
receptacles; and ground fault circuit interrupters;
2) Describe the amperage and voltage rating
of the service, the location of main disconnects and subpanels and the wiring
methods;
3) Report on the presence
of solid conductor aluminum branch circuit wiring; and
4) Report on any non-compliance with the
Carbon Monoxide Alarm Detector Act [430 ILCS 135 ] and the Smoke Detector Act
[425 ILCS 60 ].
l) When,
pursuant to the executed written contract with a client, the heating system is
inspected, the home inspector shall:
1)
Inspect the permanently installed heating equipment, including fans, pumps,
ducts, and piping; their operating controls, supports, registers, radiators,
and convectors; and visible vent systems, flues, and chimneys; and
2) Describe the energy source, the heating
equipment, and the heating method by their distinguishing
characteristics.
m) When,
pursuant to the executed written contract with a client, the cooling system is
inspected, the home inspector shall:
1)
Inspect the permanently installed central and through-wall cooling equipment,
and any operating controls; and
2)
Describe the energy source and the cooling method by their distinguishing
characteristics.
n) When,
pursuant to the executed written contract with a client, the interior is
inspected, the home inspector shall:
1)
Inspect the walls, ceilings, and floors; steps, stairways, balconies and their
railings; countertops, installed cabinets, household appliances included with
the property, doors, and windows; garage doors, and garage door operators;
and
2) Report visible signs of
water and moisture penetration into the building or signs of condensation on
building components.
o)
When, pursuant to the executed written contract with a client, the insulation
and ventilation are inspected, the home inspector shall:
1) Inspect the insulation and vapor retarders
in unfinished spaces, the ventilation of attics and foundation areas, and the
mechanical ventilation systems in attics, kitchens, bathrooms, and laundry;
and
2) Describe the insulation and
vapor retarders in unfinished spaces and the absence of insulation in
unfinished spaces at conditioned surfaces.
p) When, pursuant to the executed written
contract with a client, the fireplaces and solid fuel burning appliances are
inspected, the home inspector shall:
1)
Inspect the system components, vent systems, flues, and chimneys; and
2) Describe the fireplaces, solid fuel
burning appliances, and chimneys, and report any significant damage or
deterioration that is visible.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.