Ill. Admin. Code tit. 92, § 442.605 - Battery and Battery Compartment
a) The storage battery shall be a nominal
12-volt type. It shall be of sufficient capacity to supply all electrical
requirements but shall be rated, as specified in SAE Standard J537, not less
than either 70-ampere hours at the 20-hour discharge rate or 105-minutes at the
25-ampere discharge rate.
b) When
the battery is mounted outside the engine compartment, it shall be attached
securely in a closed, weather-tight, and vented compartment that is located and
arranged so as to provide for convenient routine servicing. The battery
compartment door, or cover, shall be secured by an adequate manually-operated
latch or fastener. Each electrical cable connecting the battery in this
compartment to the body or chassis shall be one piece between the battery
terminal connector and the first body or chassis terminal connector.
Notes
Amended at 31 Ill. Reg. 8238, effective May 25, 2007