Ill. Admin. Code tit. 77, pt. 870 - MANUFACTURED HOME INSTALLATION CODE

  1. § 870.10 - Definitions
  2. § 870.20 - Incorporated and Referenced Materials
  3. § 870.30 - Accreditation of Manufactured Home Installer Course
  4. § 870.40 - Responsibilities of Entities Offering Accredited Manufactured Home Installer Courses
  5. § 870.50 - Requirements for Accredited Manufactured Home Installer Course Curriculum
  6. § 870.55 - Reciprocity
  7. § 870.60 - Revocation of Accreditation
  8. § 870.65 - Requirements for Manufactured Home Installers License
  9. § 870.70 - Continuing Education
  10. § 870.80 - Installation Seals and Compliance Certificates
  11. § 870.90 - Requirements for the Installation of Manufactured Homes
  12. § 870.100 - Site Location
  13. § 870.110 - Support Systems
  14. § 870.120 - Structural Connections, Sealing and Patching
  15. § 870.130 - Electrical Hookup of Manufactured Homes
  16. § 870.140 - Plumbing
  17. § 870.150 - Heating and Air Conditioning
  18. § 870.160 - Natural and Liquefied Petroleum Gas Installation
  19. § 870.170 - Perimeter Enclosures
  20. § 870.190 - Tiedown Equipment Approval
  21. § 870.200 - Equipment Specifications
  22. § 870.210 - Compliance
  23. § 870.220 - Tiedown Installation Requirements
  24. § 870.230 - Manufacturer's Responsibilities
  25. § 870.240 - Penalties
  26. § 870.250 - Injunctive Relief
  27. Table A - Soil Pressure, version 15
  28. Table B - Footing Areas Required for Soil's Load-Bearing Capacity - Design Roof Load 20 Pounds Per Square Foot, version 9
  29. Table C - Footing Areas Required for Soil's Load-Bearing Capacity - Design Roof Load 30 Pounds Per Square Foot, version 8
  30. Table D - Footing Areas Required for Soil's Load-Bearing Capacity - Design Roof Load 40 Pounds Per Square Foot, version 6
  31. Table E - Pier Load and Minimum Pier Capacity for 12 Foot Wide Section (Pounds), version 5
  32. Table F - Pier Load and Minimum Pier Capacity for 14 Foot Wide Section (Pounds), version 5
  33. Table G - Pier Load and Minimum Pier Capacity for 16 Foot Wide Section (Pounds), version 3
  34. Table H - Multi-Section Fastening Schedule, version 2

Notes

Ill. Admin. Code tit. 77, pt. 870

Adopted at 4 Ill. Reg. 25, p. 148, effective July 1, 1980; codified at 8 Ill. Reg. 17513; amended at 21 Ill. Reg. 9475, effective July 1, 1997; emergency amendment at 22 Ill. Reg. 2626, effective January 14, 1998, for a maximum of 150 days; emergency expired June 13, 1998; amended at 23 Ill. Reg. 5609, effective June 1, 1999; old Part repealed by emergency rulemaking at 29 Ill. Reg. 10371 and new Part adopted by emergency rulemaking at 29 Ill. Reg. 10327, effective July 1, 2005, for a maximum of 150 days; emergency expired November 27, 2005; old Part repealed at 30 Ill. Reg. 13484, and new Part adopted at 30 Ill. Reg. 13441, effective July 28, 2006.

Amended at 47 Ill. Reg. 5231, effective 3/21/2023.

AUTHORITY: Implementing and authorized by the Illinois Manufactured Home Installers Act [430 ILCS 120 ], the Manufactured Home Quality Assurance Act [430 ILCS 117 ], and the Illinois Mobile Home Tiedown Act [210 ILCS 120 ].

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.