312 IAC 13-3-2 - Well locations
Authority: IC 25-39-4-2; IC 25-39-4-9
Affected: IC 25-39
Sec. 2.
(a) A well
shall be located as follows:
(1) To use every
natural protection to promote the maintenance of the well and its surroundings,
and to protect the quantity and quality of ground water encountered during the
construction of the well.
(2) As
far as practicable from any:
(A) high capacity
well; and
(B) known contamination
source.
(3) To protect
the well against surface water ponding, drainage, or flooding. Earthen
materials shall be placed around the pitless unit or finished well casing in a
manner to drain surface water away from the well. The finished well casing or
pitless unit shall extend at least one (1) foot above the ground level and, if
located in a designated flood hazard area, must:
(A) be at least two (2) feet above the
elevation of the regulatory flood; or
(B) be equipped with a watertight pitless
unit cap or well seal and vented to an elevation at least two (2) feet above
the elevation of the regulatory flood.
(b) This section does not apply to a
monitoring well or a dewatering well.