410 IAC 5-10.1-14 - Inspection and maintenance
Authority: IC 16-41-35-26; IC 16-41-35-29
Affected: IC 16-41-35
Sec. 14.
(a) Each
licensee or registrant shall conduct, at intervals not to exceed 6 months, a
program of inspection and maintenance of source holders, logging tools, source
handling tools, storage containers, transport containers, and injection tools
to assure proper labeling and physical condition. Records of inspection and
maintenance shall be maintained for a period of 2 years for inspection by the
board .
(b) If any inspection
conducted pursuant to 410 IAC 5-10.1-14(a) reveals damage to labeling or
components critical to radiation safety, the device shall be removed from
service until repairs have been made.
(c) The repair, opening, or modification of
any sealed source shall be performed only by persons specifically authorized to
do so by the board , the U.S. Nuclear Regulatory Commission, an agreement state
or a licensing state .