410 IAC 5-5-14 - Personnel monitoring in gamma radiography
Authority: IC 16-41-35-26; IC 16-41-35-29
Affected: IC 16-41-35
Sec. 14.
(a) No
licensee or registrant shall permit any individual to act as a radiographer or
as a radiographer's assistant unless, at all times during radiographic
operations, each such individual shall wear a direct reading pocket dosimeter
and either film badge or a thermoluminescent dosimeter. Pocket dosimeters shall
have a range from zero to at least 200 milliroentgens and shall be recharged
daily or at the start of each shift. Each film badge or thermoluminescent
dosimeter shall be assigned to and worn by only one individual.
(b) Pocket dosimeters shall be read and
exposures recorded daily. An individual's film badge or thermoluminescent
dosimeter shall be immediately processed if his pocket dosimeter is discharged
beyond its range. Reports received from the film badge or thermoluminescent
dosimeter processor and records of pocket dosimeter readings shall be
maintained for inspection by the board until it authorizes their
disposal.
(c) Pocket dosimeters
shall be checked for correct response to radiation at periods not to exceed one
year. Acceptable dosimeters shall read within plus or minus 30 percent of the
true radiation exposure.