410 IAC 5-5-5 - Locking of sources for gamma radiography
Authority: IC 16-41-35-26; IC 16-41-35-29
Affected: IC 16-41-35
Sec. 5.
(a) Each
source of radiation shall be provided with a lock or lockable outer container
designed to prevent unauthorized or accidental production of radiation or
removal or exposure of a sealed source and shall be kept locked at all times
except when under the direct surveillance of a radiographer or radiographer's
assistant , or as may be otherwise authorized pursuant to
410 IAC
5-5-15. Each storage container and source changer
likewise shall be provided with a lock and shall be kept locked when containing
sealed sources except when the container is under the direct surveillance of a
radiographer or radiographer's assistant .
(b) Radiographic exposure devices, source
changers, and storage containers, prior to being moved from one location to
another and also prior to being secured at a given location, shall be locked
and surveyed to assure that the sealed source is in the shielded
position .