410 IAC 5-5-7 - Survey instruments for gamma and temporary job site radiography
Authority: IC 16-41-35-26; IC 16-41-35-29
Affected: IC 16-41-35
Sec. 7.
(a) The
licensee or registrant shall maintain sufficient calibrated and operable
radiation survey instruments to make physical radiation surveys as required by
410 IAC 5-5-7 and
410 IAC 5-4-9 of 410 IAC
5. Instrumentation required by this section shall have such a range such that 2
milliroentgens per hour through 1 roentgen per hour can be measured.
(b) Each radiation survey instrument shall be
calibrated:
(1) at energies appropriate for
use and at intervals not to exceed 3 months and after each instrument
servicing;
(2) such that accuracy
within plus or minus 20 percent traceable to a national standard can be
demonstrated; and
(3) at two or
more widely separated points, other than zero, on each scale.
(c) Records of these calibrations
shall be maintained for two years after the calibration date for inspection by
the board.