675 IAC 15-2-10 - Wind, roof, and snow loads
Authority: IC 22-13-2-13
Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15
Sec. 10.
(a) Wind Loads. Mobile structures shall be designed for the following wind loads:
| Horizontal | 15 lb/sq. ft. |
| Vertical Upward | 9 lb/sq. ft. |
Vertical Downward (See Roof Loads, (b) below)
(b) Roof Loads. Flat, curved and pitched roofs shall be designed to resist the following live loads, applied downward on the horizontal projection:
| North Zone | 30 lb/sq. ft. |
| Middle Zone | 20 lb/sq. ft. |
(c) Required Snow Load
Click here to view Image