Iowa Admin. Code r. 567-114.20 - Sampling protocol
At a minimum, the sampling protocol must include the following:
1. Order in which
monitoring points are to be sampled, all tests and procedures needed at each
monitoring point and the order in which these procedures will be carried out,
equipment and containers to be used, procedures and precautions for their use;
precautions to avoid introducing contaminants from outside sources into
monitoring wells or samples; and how equipment must be cleaned between
uses;
2. Procedures for evacuating
each monitoring well prior to each water quality sampling;
3. Procedures for handling field blanks and
other quality assurance samples at the facility and in transit to and from the
laboratory;
4. Procedures for field
filtration of samples, if required;
5. Procedures for sample
preservation;
6. Procedures for
sample collection, labeling and handling at the facility and during transport
to the laboratory;
7. Procedures
for recording field observations and measurements;
8. Procedures for records maintenance and
data analysis; and
9. Procedures
for sampling surface water monitoring points including exact sampling locations
and depths.