Kan. Admin. Regs. § 112-110-10 - Central computer system manuals

Current through Register Vol. 40, No. 39, September 30, 2021

(a) Each CCS supplier shall provide the following manuals and diagrams for the CCS:
(1) Operation manuals;
(2) service manuals;
(3) CCS architecture diagrams; and
(4) other circuit diagrams.
(b) The required service manuals shall meet the following requirements:
(1) Accurately depict the CCS that the manual is intended to cover;
(2) provide adequate detail and be sufficiently clear in their wording and diagrams to enable a qualified repairperson to perform repair and maintenance in a manner that is conducive to the long-term reliability of the CCS;
(3) include maintenance schedules outlining the elements of the EGM that require maintenance and the frequency at which that maintenance should be carried out; and
(4) include maintenance checklists that enable EGM maintenance staff to make a record of the work performed and the results of the inspection.
(c) The required CCS architecture diagrams shall meet the following requirements:
(1) Accurately depict the CCS that the diagrams are intended to cover;
(2) provide adequate detail and be sufficiently clear in their wording and depiction to enable qualified technical staff to perform an evaluation of the design of the component; and
(3) be professionally drafted in order to meet the requirements specified in this subsection.