La. Admin. Code tit. 33, § XV-1723 - Control of Source Movement
A.
The mechanism that moves the sources of a panoramic irradiator shall require a
key to actuate. Actuation of the mechanism shall cause an audible signal to
indicate that the sources are leaving the shielded position. Only one key may
be in use at any time, and only operators or facility management may possess
it. The key shall be attached to a portable radiation survey meter by a chain
or cable. The lock for source control shall be designed so that the key may not
be removed if the sources are in an unshielded position. The door to the
radiation room shall require the same key.
B. The console of a panoramic irradiator
shall have a source position indicator that indicates when the sources are in
the fully shielded position, when they are in transit, and when the sources are
exposed.
C. The control console of
a panoramic irradiator shall have a control that promptly returns the sources
to the shielded position.
D. Each
control for a panoramic irradiator shall be clearly marked as to its
function.