La. Admin. Code tit. 56, § V-523 - Wells Greater Than 50 Feet in Depth and Where One or More Fresh Water Aquifer is Penetrated
A. The
entire well shall be filled from the bottom up to the top of the casing with
neat cement; or
B. fill material
shall be placed in the screen or in the open hole opposite the producing
aquifer. A bridge plug of not less than 50 feet in length shall be set above
the top of the screen. The remainder of the casing below the upper 30 feet
shall be filled with fill material, above which the surface plug will be set.
In addition, a bridge plug of not less than 50 feet shall be set and centered
at the depth(s) where the size of the casing is reduced and the casing of
different diameters are joined by a seal or reducer.