02-658 C.M.R. ch. 10, § 3 - Use of Existing Chimneys

10.3.1 Except as provided in Section 10.3.1.1, the required 2" minimum clearance to combustible material for existing interior chimneys and the required 1" minimum clearance to combustible material for existing exterior chimneys is not required when replacing oil- or gas-fired appliances.
10.3.1.1 The 2" clearance to combustible material for existing interior chimneys and the 1" minimum clearance to combustible material for existing exterior chimneys are required when a solid fuel appliance or a wood stove is connected to the chimney flue.
10.3.2 When installing any gas, oil or solid fuel appliance, the chimney must be lined with a clay tile liner or listed lining system compatible with the intended fuel source.

Notes

02-658 C.M.R. ch. 10, § 3

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.